# Controlling Corrosion on Hazardous Liquid and Carbon Dioxide Pipelines

- **operation:** document
- **citation:** 67 FR 70118
- **title:** Controlling Corrosion on Hazardous Liquid and Carbon Dioxide Pipelines
- **source type:** rulemaking
- **agency:** Research and Special Programs Administration
- **status:** historical
- **official:** true
- **published on:** 2002-11-20
- **effective on:** Not available
- **summary:** Controlling Corrosion on Hazardous Liquid and Carbon Dioxide Pipelines
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/federal-register-c1-31655.json
- **markdown:** https://regulus.evalyn.ai/document/federal-register-c1-31655.md
- **app url:** https://regulus.evalyn.ai/document/federal-register-c1-31655
- **source url:** https://www.federalregister.gov/documents/2002/11/20/C1-31655/controlling-corrosion-on-hazardous-liquid-and-carbon-dioxide-pipelines
**body:**

Federal Register, Volume 67 Issue 224 (Wednesday, November 20, 2002) [Federal Register Volume 67, Number 224 (Wednesday, November 20, 2002)] [Corrections] [Page 70118] From the Federal Register Online via the Government Publishing Office [ www.gpo.gov ] [FR Doc No: C1-31655] ----------------------------------------------------------------------- DEPARTMENT OF TRANSPORTATION Research and Special Programs Administration 49 CFR Part 195 [Docket No. RSPA-97-2762; Amdt. 195-73] RIN 2137-AD24 Controlling Corrosion on Hazardous Liquid and Carbon Dioxide Pipelines Correction In rule document 01-31655 beginning on page 66994 in the issue of Thursday, December 27, 2001, make the following correction: Sec. 195.573 [Corrected] On page 67006, in Sec. 195.573 (c), in the first column, the table is corrected to read as set forth below. ------------------------------------------------------------------------ Device Check frequency ------------------------------------------------------------------------ Rectifier................................. At least six times each calendar year, but with intervals not exceeding 2\1/ 2\ months. Reverse current switch.................... ............................ Diode..................................... ............................ Interference bond whose failure would ............................ jeopardize structural protection. ------------------------------------------------------------------------ Other interference bond................... At least once each calendar year, but with intervals not exceeding 15 months. ------------------------------------------------------------------------ [FR Doc. C1-31655 Filed 11-19-02; 8:45 am] BILLING CODE 1505-01-D
- **truncated:** false
- **body characters:** 1710