{"operation":"document","citation":"HAR 6-77-151","title":"HAR 6-77-151 Records","source_type":"regulation","agency":"Hawaii Public Utilities Commission","status":"current","official":true,"published_on":"1994-04-15","effective_on":"1994-09-03","summary":"pipeline, a record of each test performed under sections 6-77-145 and 6-77-146. The record must contain at least the following information: (1) The operator's name, the name of the operator's employee responsible for making the test, and the name of any test company used; (2) Test medium used; (3) T","machine_formats":{"json":"https://regulus.evalyn.ai/document/hi-har-har-6-77-151.json","markdown":"https://regulus.evalyn.ai/document/hi-har-har-6-77-151.md"},"app_url":"https://regulus.evalyn.ai/document/hi-har-har-6-77-151","source_url":"https://puc.hawaii.gov/wp-content/uploads/2026/04/HAR-6-77-Transp-of-Gas-03-31-2026.pdf","body":"pipeline, a record of each test performed under sections 6-77-145 and 6-77-146. The record must contain at least the following information: (1) The operator's name, the name of the operator's employee responsible for making the test, and the name of any test company used; (2) Test medium used; (3) Test pressure; (4) Test duration; (5) Pressure recording charts, or other record of pressure readings; (6) Elevation variations, whenever significant for the particular test; (7) Leaks and failure noted and their disposition. [Eff (Imp: 49 C.F.R. '192.517, October 1, 1990) ] (Auth: HRS '269-6) Subchapter 13 Uprating","truncated":false,"body_characters":616}