# Distribution Line Valves [49 CFR 192.181]

- **operation:** document
- **citation:** LAC 43:XIII §1141
- **title:** Distribution Line Valves [49 CFR 192.181]
- **source type:** regulation
- **agency:** Louisiana Office of Conservation
- **status:** current
- **official:** true
- **published on:** Not available
- **effective on:** Not available
- **summary:** A. Each high-pressure distribution system must have valves spaced so as to reduce the time to shut down a section of main in an emergency. The valve spacing is determined by the operating pressure, the size of the mains, and the local physical conditions. [49 CFR 192.181(a)] B. Each regulator statio
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/la-lac-43-xiii-1141.json
- **markdown:** https://regulus.evalyn.ai/document/la-lac-43-xiii-1141.md
- **app url:** https://regulus.evalyn.ai/document/la-lac-43-xiii-1141
- **source url:** https://www.doa.la.gov/doa/osr/louisiana-administrative-code/
**body:**

A. Each high-pressure distribution system must have valves spaced so as to reduce the time to shut down a section of main in an emergency. The valve spacing is determined by the operating pressure, the size of the mains, and the local physical conditions. [49 CFR 192.181(a)]

B. Each regulator station controlling the flow or pressure of gas in a distribution system must have a valve installed on the inlet piping at a distance from the regulator station sufficient to permit the operation of the valve during an emergency that might preclude access to the station. [49 CFR 192.181(b)]

C. Each valve on a main installed for operating or emergency purposes must comply with the following. [49 CFR 192.181(c)]

1. The valve must be placed in a readily accessible location so as to facilitate its operation in an emergency. [49 CFR 192.181(c)(1)]

2. The operating stem or mechanism must be readily accessible. [49 CFR 192.181(c)(2)]

3. If the valve is installed in a buried box or enclosure, the box or enclosure must be installed so as to avoid transmitting external loads to the main. [49 CFR 192.181(c)(3)]

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.