{"operation":"document","citation":"LAC 43:XIII §1313","title":"Miter Joints [49 CFR 192.233]","source_type":"regulation","agency":"Louisiana Office of Conservation","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"A. A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30 percent or more of SYMS may not deflect the pipe more than 3°. [49 CFR 192.233(a)] B. A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of less than 30 percent, but more t","machine_formats":{"json":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1313.json","markdown":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1313.md"},"app_url":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1313","source_url":"https://www.doa.la.gov/doa/osr/louisiana-administrative-code/","body":"A. A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30 percent or more of SYMS may not deflect the pipe more than 3°. [49 CFR 192.233(a)]\n\nB. A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of less than 30 percent, but more than 10 percent of SMYS may not deflect the pipe more than 12 1/2° and must be a distance equal to one pipe diameter or more away from any other miter joint, as measured from the crotch of each joint. [49 CFR 192.233(b)]\n\nC. A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 10 percent or less of SMYS may not deflect the pipe more than 90°. [49 CFR 192.233(c)]\n\nAUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.\n\nHISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:229 (April 1983), amended LR 10:521 (July 1984), LR 30:1241 (June 2004).","truncated":false,"body_characters":939}