{"operation":"document","citation":"LAC 43:XIII §1923","title":"Service Lines: Cast Iron and Ductile Iron [49 CFR 192.373]","source_type":"regulation","agency":"Louisiana Office of Conservation","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"A. Cast or ductile iron pipe less than 6 inches (152 millimeters) in diameter may not be installed for service lines. [49 CFR 192.373(a)] B. If cast iron pipe or ductile iron pipe is installed for use as a service line, the part of the service line which extends through the building wall must be of ","machine_formats":{"json":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1923.json","markdown":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1923.md"},"app_url":"https://regulus.evalyn.ai/document/la-lac-43-xiii-1923","source_url":"https://www.doa.la.gov/doa/osr/louisiana-administrative-code/","body":"A. Cast or ductile iron pipe less than 6 inches (152 millimeters) in diameter may not be installed for service lines. [49 CFR 192.373(a)]\n\nB. If cast iron pipe or ductile iron pipe is installed for use as a service line, the part of the service line which extends through the building wall must be of steel pipe. [49 CFR 192.373(b)]\n\nC. A cast iron or ductile iron service line may not be installed in unstable soil or under a building. [49 CFR 192.373(c)]\n\nAUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.\n\nHISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:234 (April 1983), amended LR 10:527 (July 1984), LR 27:1543 (September 2001), LR 30:1250 (June 2004).","truncated":false,"body_characters":725}