{"operation":"document","citation":"LAC 43:XIII §2919","title":"Transmission Lines: Testing of Repairs [49 CFR 192.719]","source_type":"regulation","agency":"Louisiana Office of Conservation","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"A. Testing of Replacement Pipe. If a segment of transmission line is repaired by cutting out the damaged portion of the pipe as a cylinder, the replacement pipe must be tested to the pressure required for a new line installed in the same location. This test may be made on the pipe before it is insta","machine_formats":{"json":"https://regulus.evalyn.ai/document/la-lac-43-xiii-2919.json","markdown":"https://regulus.evalyn.ai/document/la-lac-43-xiii-2919.md"},"app_url":"https://regulus.evalyn.ai/document/la-lac-43-xiii-2919","source_url":"https://www.doa.la.gov/doa/osr/louisiana-administrative-code/","body":"A. Testing of Replacement Pipe. If a segment of transmission line is repaired by cutting out the damaged portion of the pipe as a cylinder, the replacement pipe must be tested to the pressure required for a new line installed in the same location. This test may be made on the pipe before it is installed. [49 CFR 192.719(a)]\n\nB. Testing of Repairs Made by Welding. Each repair made by welding in accordance with §§2913, 2915, and 2917 must be examined in accordance with §1321. [49 CFR 192.719(b)]\n\nAUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.\n\nHISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:245 (April 1983), amended LR 10:537 (July 1984), LR 30:1268 (June 2004).","truncated":false,"body_characters":738}