- **summary:** A. Each component that is subject to electrical current interference must be protected by a continuing program to minimize the detrimental effects of currents. [49 CFR 193.2633(a)] B. Each cathodic protection system must be designed and installed so as to minimize any adverse effects it might cause 
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/la-lac-43-xiii-7933.json
- **markdown:** https://regulus.evalyn.ai/document/la-lac-43-xiii-7933.md
- **app url:** https://regulus.evalyn.ai/document/la-lac-43-xiii-7933
- **source url:** https://www.doa.la.gov/doa/osr/louisiana-administrative-code/
**body:**

A. Each component that is subject to electrical current interference must be protected by a continuing program to minimize the detrimental effects of currents. [49 CFR 193.2633(a)]

B. Each cathodic protection system must be designed and installed so as to minimize any adverse effects it might cause to adjacent metal components. [49 CFR 193.2633(b)]

C. Each impressed current power source must be installed and maintained to prevent adverse interference with communications and control systems. [49 CFR 193.2633(c)]

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:551.C.

HISTORICAL NOTE: Promulgated by the Department of Natural Resources, Office of Conservation, LR 44:1058 (June 2018).