{"operation":"document","citation":"P-76-048","title":"NTSB Safety Recommendation P-76-048","source_type":"guidance","agency":"National Transportation Safety Board","status":"guidance","official":true,"published_on":"1976-09-15","effective_on":"1976-09-15","summary":"USE MANUFACTURER'S PROPRIETARY TRANSITION FITTINGS, INSTALLED IN ACCORDANCE WITH WRITTEN PROCEDURES, OR USE PIPE-TO-CASING ANCHORS TO LIMIT CONTRACTION OF PLASTIC PIPE, UNTIL A COMPRESSION COUPLING IS VERIFIED BY TESTS TO BE AS STRONG AS THE PLASTIC PIPE BEING JOINED.","machine_formats":{"json":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-76-048.json","markdown":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-76-048.md"},"app_url":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-76-048","source_url":"https://data.ntsb.gov/carol-main-public/sr-details/P-76-048","body":"NTSB safety recommendation P-76-048.\n\nUSE MANUFACTURER'S PROPRIETARY TRANSITION FITTINGS, INSTALLED IN ACCORDANCE WITH WRITTEN PROCEDURES, OR USE PIPE-TO-CASING ANCHORS TO LIMIT CONTRACTION OF PLASTIC PIPE, UNTIL A COMPRESSION COUPLING IS VERIFIED BY TESTS TO BE AS STRONG AS THE PLASTIC PIPE BEING JOINED.\n\nPriority: CLASS II\n\nOverall Status: Closed - Acceptable Action\n\nIssued Date: 1976-09-15\n\nAdopted Date: 1976-07-07\n\nOverall Date Closed: 1980-05-22\n\nSynopsis: ON JANUARY 10, 1976, GAS WHICH WAS LEAKING INTO THE PATHFINDER HOTEL, IN FREMONT, NEBRASKA, IGNITED. THE GAS WAS LEAKING FROM A 2-INCH PLASTIC PIPE WHICH HAD PULLED OUT OF ITS COMPRESSION COUPLING; THE GAS SEEPED INTO THE HOTEL BECAUSE IT HAD BEEN CAPPED ABOVE BY FROZEN EARTH AND A CONCRETE ROAD SURFACE. THE HOTEL EXPLODED AND FIRE ENSUED; THE EXPLOSION AND FIRE DESTROYED THE HOTEL, DAMAGED NEARBY BUILDINGS, AND BROKE WINDOWS WITHIN A ONE-BLOCK RADIUS. THIRTY-NINE PERSONS WERE INJURED AND 20 PERSONS WERE KILLED.\n\nNtsbnumber: DCA76MP013\n\nReport Number: PAR-76-06\n\nAddressee Name: Nebraska Natural Gas Company\n\nAddressee Status: Closed--No Longer Applicable\n\nAddressee Date Closed: 1980-05-22\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1978-05-22\n\nCommunication Type: Official Correspondence\n\nCommunication Contents: NEBRASKA NATURAL GAS COMPANY LTR: WE PRESENTLY FOLLOW A POLICY THAT WAS ESTABLISHED WITHIN A FEW DAYS FOLLOWING THE ACCIDENT OF CONNECTING PLASTIC DISTRIBUTION MAINS AND SERVICES TO STEEL IN THE FOLLOWING MANNER. WE FUSE A TRANSITION (PLASTIC TO STEEL) FITTING TO THE PLASTIC PIPE. WE THEN WELD THE STEEL TO STEEL OR CONNECT THE STEEL TO STEEL WITH A COMPRESSION COUPLING. IF A COMPRESSION COUPLING IS USED, WE, IN ALL APPLICATIONS, SPOT WELD, ELECTRICALLY, A 3/4\" STEEL STRAP FROM THE EXISTING STEEL MAIN TO THE STEEL PORTION OF THE TRANSITION FITTING, THUS PROVIDING A POSITIVE ANCHOR TO ELIMINATE EVERY LIKELIHOOD OF A JOINT SEPARATION. THE JOINT IS CATHODICALLY BONDED AND WRAPPED TO INSURE ITS LONGEVITY. WE HAVE CHECKED 99 PERCENT OF THE CONNECTIONS IN OUR SYSTEM COMPANY-WIDE ON PIPE SIZES ABOVE 1\" TO INSURE THAT NO FURTHER PULLOUTS OCCUR.\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1980-05-22\n\nCommunication Type: Official Correspondence","truncated":false,"body_characters":2287}