{"operation":"document","citation":"P-85-029","title":"NTSB Safety Recommendation P-85-029","source_type":"guidance","agency":"National Transportation Safety Board","status":"guidance","official":true,"published_on":"1985-11-27","effective_on":"1985-11-27","summary":"THE NTSB RECOMMENDS THAT THE DRESSER MANUFACTURING DIVISION OF DRESSER INDUSTRIES, INC: REVIEW ITS INTERCOMPANY COMMUNICATION PRACTICES, AND REVISE THEM WHERE NECESSARY TO ENSURE THAT CUSTOMERS ORDERING A NEW OR MODIFIED PRODUCT WILL BE ADVISED OF THE PRODUCT'S LIMITATIONS.","machine_formats":{"json":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-85-029.json","markdown":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-85-029.md"},"app_url":"https://regulus.evalyn.ai/document/ntsb-recommendation-p-85-029","source_url":"https://data.ntsb.gov/carol-main-public/sr-details/P-85-029","body":"NTSB safety recommendation P-85-029.\n\nTHE NTSB RECOMMENDS THAT THE DRESSER MANUFACTURING DIVISION OF DRESSER INDUSTRIES, INC: REVIEW ITS INTERCOMPANY COMMUNICATION PRACTICES, AND REVISE THEM WHERE NECESSARY TO ENSURE THAT CUSTOMERS ORDERING A NEW OR MODIFIED PRODUCT WILL BE ADVISED OF THE PRODUCT'S LIMITATIONS.\n\nPriority: CLASS II\n\nOverall Status: Closed - Acceptable Action\n\nIssued Date: 1985-11-27\n\nAdopted Date: 1987-01-01\n\nOverall Date Closed: 1986-07-28\n\nSynopsis: AT 2:40 A.M., ON FEBRUARY 22, 1985, A POLICE PATROLMAN ON ROUTINE PATROL SMELLED STRONG NATURAL GAS ODORS AS HE CROSSED RAILROAD TRACKS WHILE HEADING SOUTH ON NORTH SIXTH STREET IN SHARPSVILLE, PENNSYLVANIA. HE RADIOED THIS INFOR MATION TO THE SHARPSVILLE POLICE DEPARTMENT DISPATCHER AT 2:42 A.M.; THE DISPATCHER RELAYED THE INFORMATION TO THE NATIONAL FUEL GAS COMPANY (GAS COMPANY) BY TELEPHONE AT 2:43 A.M., AND A GAS SERVICEMAN WAS ORDERED TO THE SCENE. AT 3:15 A.M., BEFORE THE SERVICEMAN ARRIVED AT THE SITE OF THE REPORTED LEAK, THE SHARPSVILLE INN AND A CONNECTING BUILDING EXPLODED AND BURNED, KILLING TWO PERSONS. FIREFIGHTERS ARRIVING ONSCENE MOMENTS LATER ENCOUNTERED A SECOND, SMALLER EXPLOSION WHICH INJURED ONE FIREFIGHTER. GAS COMPANY PERSONNEL SHUT OFF THE GAS TO THE LEAK SITE AT 4:15 A.M.\n\nNtsbnumber: DCA85AP009\n\nReport Number: PAR-85-02\n\nAddressee Name: Dresser Industries, Inc.\n\nAddressee Status: Closed - Acceptable Action\n\nAddressee Date Closed: 1986-07-28\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1986-01-02\n\nCommunication Type: Official Correspondence\n\nCommunication Contents: DRESSER INDUSTRIES LTR: IN KEEPING WITH DRESSER'S LONG STANDING PRACTICE OF PROVIDING LEADERSHIP IN THE AREA OF ENHANCING PRODUCT AND INDUSTRY SAFETY, WE WILL REVISE OUR PRACTICES TO INCLUDE THE REDUNDANT INFORMATION, INSTRUCTIONS, AND SPECIFICATIONS FOR \"NON-STANDARD\" PRODUCTS.\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1986-06-04\n\nCommunication Type: Official Correspondence\n\nCommunication Contents: ENCLOSED PLEASE FIND A COPY OF A MEMO FROM J. VAN HOUTTE TO D.M. RODI, OUR MANAGER OF MARKETING COMMUNICATIONS, REVISING OUR INTERCOMPANY COMMUNICATION PRACTICES TO INCLUDE REDUNDANT INFORMATION, INSTRUCTIONS, AND SPECIFICATIONS FOR \"NONSTANDARD\" PRODUCTS.\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1986-03-25\n\nCommunication Type: Official Correspondence\n\nAddressee Organization Type: P-Private Industry\n\nCommunication Date: 1986-07-28\n\nCommunication Type: Official Correspondence","truncated":false,"body_characters":2544}