{"operation":"document","citation":"16 NYCRR 255.113","title":"255.113 Longitudinal joint factor (E) for steel pipe.","source_type":"regulation","agency":"New York State Public Service Commission","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"Transmission and Distribution of Gas. (a) The longitudinal joint factor to be used in the design formula in section 255.105 of this Part is determined in accordance with the following table:\n\nSpecification* | Pipe Class | Longitudinal Joint Factor (E)\nASTM A 53/A 53M | Seamless | 1.00\nElectric resistance welded | 1.00\nFurnace butt welded | .60\nASTM A 106 | Seamless | 1.00\nASTM A 211 | Spiral wel","machine_formats":{"json":"https://regulus.evalyn.ai/document/ny-nycrr-255-113.json","markdown":"https://regulus.evalyn.ai/document/ny-nycrr-255-113.md"},"app_url":"https://regulus.evalyn.ai/document/ny-nycrr-255-113","source_url":"https://govt.westlaw.com/nycrr/Document/I505c6fe3cd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)","body":"(a) The longitudinal joint factor to be used in the design formula in section 255.105 of this Part is determined in accordance with the following table:\n\nSpecification* | Pipe Class | Longitudinal Joint Factor (E)\nASTM A 53/A 53M | Seamless | 1.00\nElectric resistance welded | 1.00\nFurnace butt welded | .60\nASTM A 106 | Seamless | 1.00\nASTM A 211 | Spiral welded steel pipe | .80\nASTM A 333 | Seamless | 1.00\nElectric resistance welded | 1.00\nASTM A 381 | Double submerged arc welded | 1.00\nASTM A 671 | Electric fusion welded | 1.00\nASTM A 672 | Electric fusion welded | 1.00\nASTM A 691 | Electric fusion welded | 1.00\nAPI Spec 5L | Seamless | 1.00\nElectric resistance welded | 1.00\nElectric flash welded | 1.00\nSubmerged arc welded | 1.00\nFurnace butt welded | .60\nOther | Pipe over four inches (102 millimeters) | .80\nPipe four inches (102 millimeters) or less | .60\n\nAs described in section 10.3 of this Title.\n\n(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for Other.","truncated":false,"body_characters":1047}