- **summary:** Transmission and Distribution of Gas. (a) Each plastic service outside a building must be installed below ground level, except that:

(1) it may be installed in accordance with section 255.321(l) of this Part; and

(2) it may terminate above ground level and outside the building if:

(i) the aboveground part of the plastic service line is protected against deterioration and external damage.

(ii
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/ny-nycrr-255-375.json
- **markdown:** https://regulus.evalyn.ai/document/ny-nycrr-255-375.md
- **app url:** https://regulus.evalyn.ai/document/ny-nycrr-255-375
- **source url:** https://govt.westlaw.com/nycrr/Document/I505d0c02cd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)
**body:**

(a) Each plastic service outside a building must be installed below ground level, except that:

(1) it may be installed in accordance with section 255.321(l) of this Part; and

(2) it may terminate above ground level and outside the building if:

(i) the aboveground part of the plastic service line is protected against deterioration and external damage.

(ii) the plastic service line is not used to support external loads; and

(iii) the riser portion of the service line meets the design requirements of section 255.204 of this Part.

(b) Each plastic service line inside a building must be protected against external damage and must not be exposed.