# 255.471 External corrosion control: test leads.

- **operation:** document
- **citation:** 16 NYCRR 255.471
- **title:** 255.471 External corrosion control: test leads.
- **source type:** regulation
- **agency:** New York State Public Service Commission
- **status:** current
- **official:** true
- **published on:** Not available
- **effective on:** Not available
- **summary:** Transmission and Distribution of Gas. (a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive.

(b) Each test lead wire must be attached to the pipeline so as to minimize stress concentration on the pipe.

(c) Each bared test lead wire and bared metallic area at point of connection to the pipeline must be coated with an electrical
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/ny-nycrr-255-471.json
- **markdown:** https://regulus.evalyn.ai/document/ny-nycrr-255-471.md
- **app url:** https://regulus.evalyn.ai/document/ny-nycrr-255-471
- **source url:** https://govt.westlaw.com/nycrr/Document/I505d0c32cd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)
**body:**

(a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive.

(b) Each test lead wire must be attached to the pipeline so as to minimize stress concentration on the pipe.

(c) Each bared test lead wire and bared metallic area at point of connection to the pipeline must be coated with an electrical insulating material compatible with the pipe coating and the insulation on the wire.