{"operation":"document","citation":"16 NYCRR 255.821","title":"255.821 Leaks: nonreportable reading.","source_type":"regulation","agency":"New York State Public Service Commission","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"Transmission and Distribution of Gas. Whenever an operator conducts an annual leakage survey of all mains, or a portion of the mains, in its distribution system, any sustained reading of four percent or less gas-in-air on a CGI at an isolated test point outside the curbline or shoulder of the road can be considered a nonreportable reading except where found in manholes, vaults or catch basins.","machine_formats":{"json":"https://regulus.evalyn.ai/document/ny-nycrr-255-821.json","markdown":"https://regulus.evalyn.ai/document/ny-nycrr-255-821.md"},"app_url":"https://regulus.evalyn.ai/document/ny-nycrr-255-821","source_url":"https://govt.westlaw.com/nycrr/Document/I505da85dcd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)","body":"Whenever an operator conducts an annual leakage survey of all mains, or a portion of the mains, in its distribution system, any sustained reading of four percent or less gas-in-air on a CGI at an isolated test point outside the curbline or shoulder of the road can be considered a nonreportable reading except where found in manholes, vaults or catch basins.","truncated":false,"body_characters":358}