# KINDER MORGAN LIQUID TERMINALS, LLC — Notice of Amendment

- **operation:** document
- **citation:** CPF 12022037NOA
- **title:** KINDER MORGAN LIQUID TERMINALS, LLC — Notice of Amendment
- **source type:** enforcement
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2022-03-15
- **effective on:** Not available
- **summary:** CLOSED notice of amendment citing 195.402(c)(3), 195.402(f).
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-enforcement-12022037noa.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-enforcement-12022037noa.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-enforcement-12022037noa
- **source url:** https://primis.phmsa.dot.gov/enforcement-data/case/12022037NOA
**body:**

Notice of Amendment involving KINDER MORGAN LIQUID TERMINALS, LLC. PHMSA's enforcement data identifies the cited regulations as 195.402(c)(3),  195.402(f). The case was opened on 2022-03-15 and is reported as closed as of 2022-06-02. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

12022037NOA_Closure Letter_06022022_(21-199002).pdf: https://primis.phmsa.dot.gov/enforcement-documents/12022037NOA/12022037NOA_Closure%20Letter_06022022_(21-199002).pdf

12022037NOA_Closure Letter_06022022_(21-199002)_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/12022037NOA/12022037NOA_Closure%20Letter_06022022_(21-199002)_text.pdf

12022037NOA_Notice of Amendment_03152022_(21-199002).pdf: https://primis.phmsa.dot.gov/enforcement-documents/12022037NOA/12022037NOA_Notice%20of%20Amendment_03152022_(21-199002).pdf

12022037NOA_Notice of Amendment_03152022_(21-199002)_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/12022037NOA/12022037NOA_Notice%20of%20Amendment_03152022_(21-199002)_text.pdf

12022037NOA_Operator Response to Notice_03282022_(21-199002).pdf: https://primis.phmsa.dot.gov/enforcement-documents/12022037NOA/12022037NOA_Operator%20Response%20to%20Notice_03282022_(21-199002).pdf

12022037NOA_Notice of Amendment_03152022_(21-199002)_text.pdf

NOTICE OF AMENDMENT
OVERNIGHT EXPRESS DELIVERY
March 15, 2022
Mr. Steven J. Kean
President and Chief Executive Officer
Kinder Morgan Liquid Terminals, LLC
1001 Louisiana Street, Suite 1000
Houston, Texas 77002
CPF 1-2022-037-NOA
Dear Mr. Kean:
From June 21, 2021 through September 15, 2021, a representative of the Pipeline and Hazardous
Materials Safety Administration (PHMSA) pursuant to Chapter 601 of 49 United States Code
inspected Kinder Morgan Liquid Terminals, LLC’s (KMLT) procedures in Cincinnati and Dayton,
Ohio, Indianapolis, Indiana, and Argo and Wood River, Illinois.
On the basis of the inspection, PHMSA has identified the apparent inadequacies found within
KMLT’s plans or procedures, as described below:
1. § 195.402 Procedural manual for operations, maintenance, and emergencies.
(a) …
(c) Maintenance and normal operations. The manual required by
paragraph (a) of this section must include procedures for the following
to provide safety during maintenance and normal operations:
(1) …
(3) Operating, maintaining, and repairing the pipeline system in
accordance with each of the requirements of this subpart and subpart
H of this part.
KMLT’s procedures for maintenance and normal operations were inadequate to ensure safe
operation of a pipeline facility. Specifically, KMLT’s T-O&M 903 External Corrosion Control
for Buried or Submerged Pipelines, dated 01/13/21 (Corrosion Manual) failed to require and verify
that supervisors maintain a thorough knowledge of that portion of the corrosion control procedures



CPF 1-2022-037-NOA
established under § 195.402(c)(3) for which they are responsible for insuring compliance in
accordance with § 195.555.1
KMLT’s Corrosion Manual Section 3.1 stated in part:
Supervisors and personnel responsible for insuring compliance with the corrosion
control processes in this procedure shall maintain a thorough knowledge of
corrosion processes and these procedures through means such as:
• Reviewing this procedure during annual corrosion team meetings or
individually if team meetings are not possible. Refer to T-O&M Procedure
003, Procedure Review.
• Attending National Association of Corrosion Engineers Training Courses
• Attending/completing other industry recognized corrosion courses
• On the job application of the procedures
• In-house corrosion training and presentations
However, the Corrosion Manual failed to provide details on how KMLT verifies that supervisors
maintain a thorough knowledge of the corrosion control procedures. Furthermore, the Corrosion
Manual failed to explicitly require that supervisors review the procedures for which they are
responsible for.
Therefore, KMLT failed to require and verify that supervisors maintain a thorough knowledge of
that portion of the corrosion control procedures established under § 195.402(c)(3) for which they
are responsible for insuring compliance in accordance with § 195.555. KMLT must revise its
procedures to address this requirement.
2. § 195.402 Procedural manual for operations, maintenance, and emergencies.
(a) …
(f) Safety-related condition reports. The manual required by
paragraph (a) of this section must include instructions enabling
personnel who perform operation and maintenance activities to
recognize conditions that potentially may be safety-related conditions
that are subject to the reporting requirements of § 195.55.
KMLT’s procedures for safety-related conditions were inadequate to ensure safe operation of a
pipeline facility. Specifically, KMLT’s T-O&M 214 Reporting Pipeline Safety-Related
Conditions, dated 05/27/21 (SRC Procedure) failed to include instructions enabling personnel who
perform operation and maintenance activities to recognize conditions that potentially may be
safety-related conditions that are subject to the reporting requirements of § 195.55.2
1 49 C.F.R. § 195.555 What are the qualifications for supervisors?
You must require and verify that supervisors maintain a thorough knowledge of that portion of the corrosion control
procedures established under § 195.402(c)(3) for which they are responsible for insuring compliance.
2 49 C.F.R. § 195.55 Reporting safety-related conditions.
(a) Except as provided in paragraph (b) of this section, each operator shall report in accordance with § 195.56 the
existence of any of the following safety-related conditions involving pipelines in service:
12022037NOA_Notice of Amendment_03152022_(21-199002)_text Page 2 of 4



CPF 1-2022-037-NOA
While the SRC Procedure did include a process for reporting safety-related conditions, it did not
include adequate instructions for operations and maintenance personnel to recognize conditions
that may be safety-related conditions. When PHMSA requested additional information regarding
instructions enabling personnel to recognize safety-related conditions, KMLT could not provide
anything further.
Therefore, KMLT failed to include instructions in its written procedures enabling personnel who
perform operation and maintenance activities to recognize conditions that potentially may be
safety-related conditions in accordance with § 195.402(f). KMLT must revise its procedures to
address this requirement.
Response to this Notice
This Notice is provided pursuant to 49 U.S.C. § 60108(a) and 49 C.F.R. § 190.206. Enclosed as
part of this Notice is a document entitled Response Options for Pipeline Operators in Enforcement
Proceedings.
Please refer to this document and note the response options. Be advised that all material you
submit in response to this enforcement action is subject to being made publicly available. If you
believe that any portion of your responsive material qualifies for confidential treatment under 5
U.S.C. § 552(b), along with the complete original document you must provide a second copy of
the document with the portions you believe qualify for confidential treatment redacted and an
explanation of why you believe the redacted information qualifies for confidential treatment under
5 U.S.C. § 552(b).
Following the receipt of this Notice, you have 30 days to submit written comments, revised
procedures, or a request for a hearing under § 190.211. If you do not respond within 30 days of
(1) General corrosion that has reduced the wall thickness to less than that required for the maximum operating
pressure, and localized corrosion pitting to a degree where leakage might result.
(2) Unintended movement or abnormal loading of a pipeline by environmental causes, such as an earthquake,
landslide, or flood, that impairs its serviceability.
(3) Any material defect or physical damage that impairs the serviceability of a pipeline.
(4) Any malfunction or operating error that causes the pressure of a pipeline to rise above 110 percent of its
maximum operating pressure.
(5) A leak in a pipeline that constitutes an emergency.
(6) Any safety-related condition that could lead to an imminent hazard and causes (either directly or indirectly by
remedial action of the operator), for purposes other than abandonment, a 20 percent or more reduction in operating
pressure or shutdown of operation of a pipeline.
(b) A report is not required for any safety-related condition that -
(1) Exists on a pipeline that is more than 220 yards (200 meters) from any building intended for human occupancy
or outdoor place of assembly, except that reports are required for conditions within the right-of-way of an active
railroad, paved road, street, or highway, or that occur offshore or at onshore locations where a loss of hazardous
liquid could reasonably be expected to pollute any stream, river, lake, reservoir, or other body of water;
(2) Is an accident that is required to be reported under § 195.50 or results in such an accident before the deadline for
filing the safety-related condition report; or
(3) Is corrected by repair or replacement in accordance with applicable safety standards before the deadline for filing
the safety-related condition report, except that reports are required for all conditions under paragraph (a)(1) of this
section other than localized corrosion pitting on an effectively coated and cathodically protected pipeline.
12022037NOA_Notice of Amendment_03152022_(21-199002)_text Page 3 of 4



CPF 1-2022-037-NOA
receipt of this Notice, this constitutes a waiver of your right to contest the allegations in this Notice
and authorizes the Associate Administrator for Pipeline Safety to find facts as alleged in this Notice
without further notice to you and to issue an Order Directing Amendment. If your plans or
procedures are found inadequate as alleged in this Notice, you may be ordered to amend your plans
or procedures to correct the inadequacies (49 C.F.R. § 190.206). If you are not contesting this
Notice, we propose that you submit your amended procedures to my office within 30 days of
receipt of this Notice. This period may be extended by written request for good cause. Once the
inadequacies identified herein have been addressed in your amended procedures, this enforcement
action will be closed.
It is requested (not mandated) that Kinder Morgan Liquid Terminals, LLC maintain documentation
of the safety improvement costs associated with fulfilling this Notice of Amendment
(preparation/revision of plans, procedures) and submit the total to Robert Burrough, Director,
Eastern Region, Pipeline and Hazardous Materials Safety Administration, 840 Bear Tavern Road,
Suite 300, West Trenton, NJ 08628. In correspondence concerning this matter, please refer to CPF
1-2022-037-NOA and, for each document you submit, please provide a copy in electronic format
whenever possible. Smaller files may be emailed to robert.burrough@dot.gov. Larger files should
be sent on USB flash drive accompanied by the original paper copy to the Eastern Region Office.
Sincerely,
Robert Burrough
Director, Eastern Region
Pipeline and Hazardous Materials Safety Administration
Enclosure: Response Options for Pipeline Operators in Enforcement Proceedings
12022037NOA_Notice of Amendment_03152022_(21-199002)_text Page 4 of 4

12022037NOA_Closure Letter_06022022_(21-199002)_text.pdf

OVERNIGHT EXPRESS DELIVERY
June 2, 2022
Mr. Steven J. Kean
President and Chief Executive Officer
Kinder Morgan Liquid Terminals, LLC
1001 Louisiana Street, Suite 1000
Houston, Texas 77002
CPF 1-2022-037-NOA
Dear Mr. Kean:
From June 21, 2021 through September 15, 2021, a representative of the Pipeline and Hazardous
Materials Safety Administration (PHMSA) pursuant to Chapter 601 of 49 United States Code
inspected Kinder Morgan Liquid Terminals, LLC’s (KMLT) procedures in Cincinnati and Dayton,
Ohio, Indianapolis, Indiana, and Argo and Wood River, Illinois. As a result of the inspection,
KMLT was issued a Notice of Amendment (NOA) on March 15, 2022, which proposed
amendment of your procedures. KMLT submitted its amended procedures on March 28, 2022.
On May 26, 2022 PHMSA held a meeting to address its concerns with KMLT regarding the
inadequacies identified in the amended procedures. KMLT re-submitted its amended procedures
on May 26, 2022. My staff reviewed the amended procedures, and it appears that the inadequacies
outlined in this Notice of Amendment have been corrected.
This letter is to inform you no further action is necessary and this case is now closed. Thank you
for your cooperation.
Sincerely,
Robert Burrough
Director, Eastern Region
Pipeline and Hazardous Materials Safety Administration