# ENBRIDGE ENERGY, LIMITED PARTNERSHIP — Notice of Amendment

- **operation:** document
- **citation:** CPF 320071011M
- **title:** ENBRIDGE ENERGY, LIMITED PARTNERSHIP — Notice of Amendment
- **source type:** enforcement
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2007-06-27
- **effective on:** Not available
- **summary:** CLOSED notice of amendment citing 192.465(d), 192.715(b), 192.727(b), 192.751.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-enforcement-320071011m.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-enforcement-320071011m.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-enforcement-320071011m
- **source url:** https://primis.phmsa.dot.gov/enforcement-data/case/320071011M
**body:**

Notice of Amendment involving ENBRIDGE ENERGY, LIMITED PARTNERSHIP. PHMSA's enforcement data identifies the cited regulations as 192.465(d),  192.715(b),  192.727(b),  192.751. The case was opened on 2007-06-27 and is reported as closed as of 2007-06-27. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

320071011M_notice of amendment_062720071.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320071011M/320071011M_notice%20of%20amendment_062720071.pdf

320071011m_notice of amendment_062720071_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320071011M/320071011m_notice%20of%20amendment_062720071_text.pdf

320071011m_notice of amendment_062720071_text.pdf

U. S. Department
of Transportation
Pipeline ond
HozoNtous Moteriols Sofety
Admlnlstrotlon
901 Locust Street, Suite 462
Kansas City, MO 64106-2641
NOTICE OF AMKNDMKNT
CKRTIFIK MAIL - RETURN CEIPT RE UESTKD
June 27, 2007
Mr. Terry L. McGill
President
Enbridge Energy Partners, LP
1100 Louisiana, Suite 3300
Houston, TX 77002
CPF 3-2007-1011M
Dear Mr. McGill:
On October 17-20, 2005, representatives of the Pipeline and Hazardous Materials Safety
Administration (PHMSA) and the Michigan Public Service Commission, pursuant to Chapter
601 of 49 United States Code inspected your procedures for Enbridge Energy's Vector
Pipeline operation and maintenance in Griffith, IN.
On the basis of the inspection, PHMSA has identified the apparent inadequacies found within
Enbridge Energy's (Enbridge's) Vector Pipeline plans or procedures, as described below:
$192. 465 External corrosion control: Monitoring
(d) Each operator shall take prompt remedial action to correct any deficiencies
indicated by the monitoring.
Enbridge's procedure in the Corrosion Control Book, Chapter 3, Section 6 needs to be
clarified to indicate the timeframe for the remediation of deficiencies.



2. f192. 715 Transmission lines: Permanent fieM repair of welds
Each weld that is unacceptable under $192. 241(c) must be repaired as follows:
(b) A weld may be repaired in accordance with $192. 245 whIe the segment of
transmission line is in service if:
(1) The weld is not leaking:
(2) The pressure in the segment is reduced so that it does not produce a
stress that is more than 20 percent of the SMYS of the pipe; and
(3) Grinding of the defective area can be limited so that at least 1/8-inch
(3. 2 millimeters) thickness in the pipe weld remains.
Enbridge's procedures in Book 4, Section 02-02-07 need to be clarified to address
these issues specifically for gas lines.
3. f192. 727 Abandonment or inactivation of faciTities
(b) Each pipeline abandoned in place must be disconnected from all sources and
supplies of gas; purged of gas; in the case of offshore pipelines, filled with water
or inert materials; and sealed at the ends. However, the pipeline need not be
purged when the volume of gas is so small that there is no potential hazard.
Enbridge's procedures in Book 3, Section 06-02-04 need to clarify abandonment
versus deactivated pipelines.
4. $192. 751 Prevention of accidental ignition
Each operator shall take steps to minimize the danger of accidental ignition of
gas in any structure or area where the presence of gas constitutes a hazard of Are
or explosion, including the following:
(c) Post warning signs, where appropriate.
Enbridge's procedures in Book 3, Section 03-02-03 needs to be clarified as to where
warning signs are posted.
Res nse to this N tice
This Notice is provided pursuant to 49 U. S. C. $ 60108(a) and 49 C. F. R. $ 190. 237. Enclosed
as part of this Notice is a document entitled Response Options for Pipeline Operators in
Compliance Proceedings. Please refer to this document and note the response options. Be
advised that all material you submit in response to this enforcement action is subject to being
made publicly available. If you believe that any portion of your responsive material qualifies
for confidential treatment under 5 U. S. C. 552(b), along with the complete original document
you must provide a second copy of the document with the portions you believe qualify for
confidential treatment redacted and an explanation of why you believe the redacted
information qualifies for confidential treatment under 5 U. S. C. 552(b). If you do not respond
within 30 days of receipt of this Notice, this constitutes a waiver of your right to contest the
allegations in this Notice and authorizes the Associate Administrator for Pipeline Safety to
find facts as alleged in this Notice without further notice to you and to issue a Final Order.



If, after opportunity for a hearing, your plans or procedures are found inadequate as alleged in
this Notice, you may be ordered to amend your plans or procedures to correct the
inadequacies (49 C. F. R. $ 190. 237). If you are not contesting this Notice, we propose that
you submit your amended procedures to my of5ce within 30 days of receipt of this Notice.
This period may be extended by written request for good cause. Once the inadequacies
identified herein have been addressed in your amended procedures, this enforcement action
will be closed.
Your staff has submitted revised procedures addressing all four items noted in this Notice.
PHMSA has reviewed the amended procedures, and it appears that the inadequacies outlined
in this Notice of Amendment have been corrected. Corrected procedures have been received
in electronic format.
No further action is necessary and this case is now closed. Thank you for your cooperation.
/
In correspondence concerning this matter, please refer to CPF 3-2007-1011M and, for each
document you submit, please provide a copy in electronic format whenever possible.
Sincerely,
Ivan A. Huntoon
Director, Central Region
Pipeline and Hazardous Materials Safety Administration
Enclosure: Response Options for Pipeline Operators in Compliance Proceedings
- **truncated:** false
- **body characters:** 5900
