# BETA OFFSHORE — Notice of Amendment

- **operation:** document
- **citation:** CPF 520085034M
- **title:** BETA OFFSHORE — Notice of Amendment
- **source type:** enforcement
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2008-09-15
- **effective on:** Not available
- **summary:** CLOSED notice of amendment citing 195.214(a), 195.222(a), 195.228(b).
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-enforcement-520085034m.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-enforcement-520085034m.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-enforcement-520085034m
- **source url:** https://primis.phmsa.dot.gov/enforcement-data/case/520085034M
**body:**

Notice of Amendment involving BETA OFFSHORE. PHMSA's enforcement data identifies the cited regulations as 195.214(a),  195.222(a),  195.228(b). The case was opened on 2008-09-15 and is reported as closed as of 2009-06-19. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

520085034M_notice of amendment_09152008.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520085034M/520085034M_notice%20of%20amendment_09152008.pdf

520085034M_operator_response_03052009.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520085034M/520085034M_operator_response_03052009.pdf

520085034M_notice of amendment_09152008.pdf

U.S. Department 12300 W. Dakota Ave., Suite 110
of Transportation Lakewood, CO 80228
Pipeline and
Hazardous Materials Safety
Administration
NOTICE OF AMENDMENT
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
September 15, 2008
Mr. Robert Pyle
Manager, Pipeline and Marine Logistics
Pacific Energy Resources LTD
111 West Ocean Blvd., Suite 1240
Long Beach, CA 90802
CPF 5-2008-5034M
Dear Mr. Pyle:
On August 25-27,2008, representatives of the Pipeline and Hazardous Materials Safety
Administration (PHMSA) pursuant to Chapter 601 of 49 United States Code inspected Pacific
Energy Resources' procedures for Operations and Maintenance (O&M) Procedural Manuals in
Long Beach California.
On the basis of the inspection, PHMSA has identified the apparent inadequacies found within
Pacific Energy Resources' plans or procedures, as described below:
1. §195.214 Welding procedures
(a) Welding must be performed by a qualified welder in accordance with welding
procedures qualified under Section 5 of API 1104 or Section IX of the ASME Boiler
and Pressure Vessel Code (ibr, see § 195.3) . The quality of the test welds used to
qualify the welding procedure shall be determined by destructive testing.



Pacific Energy Resources is not specific in its O&M manuals regarding what section and
edition of API 1104 need to be used to qualify its 'Welding Procedures'.
2. §195.222 Welders: Qualification of welders.
(a) Each welder must be qualified in accordance with section 6 of API 1104 (ibr,
see §195.3 or section IX ofthe ASlVIE Boiler and Pressure Vessel Code, (ibr, see §
195.3) except that a welder qualified under an earlier edition than listed in § 195.3
may weld but may not re-qualify under that earlier edition.
Pacific Energy Resources requires its welder to be qualified under Section 3 of API
1104. CFR 49 Part 195.222 requires all welders to be qualified under Section 6 of API
1104. Pacific Energy needs to change its O&M procedural manual to reference
Section 6 and specify the correct edition of API 1104.
3. §195.228 Welds and welding inspection: Standards of acceptability.
(b) The acceptability of a weld is determined according to the standards in Section
9 of API 1104. However, if a girth weld is unacceptable under those standards for a
reason other than a crack, and if Appendix A to API 1104 (ibr, see § 195.3) applies
to the weld, the acceptability of the weld may be determined under that appendix.
Pacific Energy Resources requires its weld acceptability to be inspected under Section 6
of API 1104. CFR 49 Part 195.288 requires weld inspection to be performed under
Section 9 of API 1104. Pacific Energy needs to change its O&M procedural manual to
reference Section 9 and specify the correct edition of API 1104.
Response to this Notice
This Notice is provided pursuant to 49 U.S.C. § 60108(a) and 49 C.F.R. § 190.237. Enclosed as
part of this Notice is a document entitled Response Options for Pipeline Operators in
Compliance Proceedings. Please refer to this document and note the response options. Be
advised that all material you submit in response to this enforcement action is subject to being
made publicly available. If you believe that any portion of your responsive material qualifies
for confidential treatment under 5 U.S.C. 552(b), along with the complete original document
you must provide a second copy of the document with the portions you believe qualify for
confidential treatment redacted and an explanation of why you believe the redacted information
qualifies for confidential treatment under 5 U.S.C. 552(b). If you do not respond within 30 days
of receipt of this Notice, this constitutes a waiver of your right to contest the allegations in this
Notice and authorizes the Associate Administrator for Pipeline Safety to find facts as alleged in
this Notice without further notice to you and to issue a Final Order.
2



If, after opportunity for a hearing, your plans or procedures are found inadequate as alleged in
this Notice, you may be ordered to amend your plans or procedures to correct the inadequacies
(49 C.F.R. § 190.237). If you are not contesting this Notice, we propose that you submit your
amended procedures to my office within 60 days ofreceipt ofthis Notice. This period may be
extended by written request for good cause. Once the inadequacies identified herein have been
addressed in your amended procedures, this enforcement action will be closed.
In correspondence concerning this matter, please refer to CPF 5-2008-5034M and, for each
document you submit, please provide a copy in electronic format whenever possible.
Sincerel
Y >/2/ /
Chris Hoidal
Director, Western Region
Pipeline and Hazardous Materials Safety Administration
cc: PHP-60 Compliance Registry
PHP-500 H. Monfared (#122435)
Enclosure: Response Options for Pipeline Operators in Compliance Proceedings
3
- **truncated:** false