# NORGASCO INC — Warning Letter

- **operation:** document
- **citation:** CPF 520150001W
- **title:** NORGASCO INC — Warning Letter
- **source type:** enforcement
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2015-02-24
- **effective on:** Not available
- **summary:** CLOSED warning letter citing 192.475(b), 192.616(d), 192.616(h).
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-enforcement-520150001w.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-enforcement-520150001w.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-enforcement-520150001w
- **source url:** https://primis.phmsa.dot.gov/enforcement-data/case/520150001W
**body:**

Warning Letter involving NORGASCO INC. PHMSA's enforcement data identifies the cited regulations as 192.475(b),  192.616(d),  192.616(h). The case was opened on 2015-02-24 and is reported as closed as of 2015-02-24. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

520150001W_Operator Response to Notice_03162015.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520150001W/520150001W_Operator%20Response%20to%20Notice_03162015.pdf

520150001W_warning letter_02242015.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520150001W/520150001W_warning%20letter_02242015.pdf

520150001W_warning letter_02242015_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520150001W/520150001W_warning%20letter_02242015_text.pdf

520150001W_warning letter_02242015_text.pdf

WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
February 24, 2015
Mr. Richard J. Cathriner
President
Norgasco, Inc.
4341 B Street, Suite 306
Anchorage, Alaska 99503
CPF 5-2015-0001W
Dear Mr. Cathriner:
On November 13, 2014, a representative of the Pipeline and Hazardous Materials Safety
Administration (PHMSA), pursuant to Chapter 601 of 49 United States Code, inspected your
Public Awareness Plan and procedures for Operations and Maintenance in Anchorage,
Alaska.
As a result of the inspection, it appears that you have committed a probable violation of the
Pipeline Safety Regulations, Title 49, Code of Federal Regulations. The items inspected and
the probable violations are:
1. 192.616(h) Public awareness.
(h) Operators in existence on June 20, 2005, must have completed their written
programs no later than June 20, 2006. The operator of a master meter or
petroleum gas system covered under paragraph (j) of this section must complete
development of its written procedure by June 13, 2008. Upon request, operators
must submit their completed programs to PHMSA or, in the case of an intrastate
pipeline facility operator, the appropriate State agency.
A written Public Awareness Plan was not completed until July 2011, which is five years after
the regulatory deadline for completion of a written program.



2. 192.616(d) Public awareness.
(d) The operator's program must specifically include provisions to educate the
public, appropriate government organizations, and persons engaged in
excavation related activities on:
(1) Use of a one-call notification system prior to excavation and other damage
prevention activities;
(2) Possible hazards associated with unintended releases from a gas pipeline
facility;
(3) Physical indications that such a release may have occurred;
(4) Steps that should be taken for public safety in the event of a gas pipeline
release; and
(5) Procedures for reporting such an event.
The Public Awareness message on Norgasco's web site was missing key educational
information that was contained in Norgasco’s printed Public Awareness Message.
Specifically, the web site lacked the information on the proper steps the public should take in
the event of a gas pipeline release.
3. 192.475(b) Internal corrosion control: General.
(b) Whenever any pipe is removed from a pipeline for any reason, the internal
surface must be inspected for evidence of corrosion. If internal corrosion is
found—
(1) The adjacent pipe must be investigated to determine the extent of internal
corrosion;
(2) Replacement must be made to the extent required by the applicable
paragraphs of §§ 192.485, 192.487, or 192.489; and
(3) Steps must be taken to minimize the internal corrosion.
Norgasco was unable to provide any records of examination for the pipe that was removed
due to internal corrosion. Norgasco had replaced certain sections of steel pipe that failed due
to frost heave. Norgasco has no record of inspecting these removed sections of pipe.
Under 49 United States Code, § 60122, you are subject to a civil penalty not to exceed
$200,000 per violation per day the violation persists up to a maximum of $2,000,000 for a
related series of violations. For violations occurring prior to January 4, 2012, the maximum
penalty may not exceed $100,000 per violation per day, with a maximum penalty not to
exceed $1,000,000 for a related series of violations. We have reviewed the circumstances and
supporting documents involved in this case, and have decided not to conduct additional
enforcement action or penalty assessment proceedings at this time. We advise you to correct
the items identified in this letter. Failure to do so will result in Norgasco being subject to
additional enforcement action.



No reply to this letter is required. If you choose to reply, in your correspondence please refer
to CPF 5-2015-0001W and for each document you submit, please provide a copy in
electronic format to PHP-WRADMIN@dot.gov whenever possible. Be advised that all
material you submit in response to this enforcement action is subject to being made publicly
available. If you believe that any portion of your responsive material qualifies for
confidential treatment under 5 U.S.C. 552(b), along with the complete original document you
must provide a second copy of the document with the portions you believe qualify for
confidential treatment redacted and an explanation of why you believe the redacted
information qualifies for confidential treatment under 5 U.S.C. 552(b).
Sincerely,
Chris Hoidal
Director, Western Region
Pipeline and Hazardous Materials Safety Administration
cc: PHP-60 Compliance Registry
PHP-500 D. Hassell
Activity 146206