{"operation":"document","citation":"PHMSA Hazmat Incident E-2005120089","title":"PHMSA Hazmat Incident E-2005120089 — PHENOL, MOLTEN — HOQUIAM, WA","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2005-12-01","summary":"Serious reporter-submitted hazardous materials transportation incident on 2005-12-01 in HOQUIAM, WA.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2005120089.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2005120089.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2005120089","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=fvmmK79iiqDsQ1s9B%2FeHFw%3D%3D","body":"PHMSA hazardous materials incident report E-2005120089.\nIncident date: 2005-12-01.\nLocation: HOQUIAM, WA.\nMode: Rail.\nCarrier/reporter: Paneltech.\nShipper: Dakota Gasification Company.\nMaterials: UN2312; PHENOL, MOLTEN; hazard class 6.1; 375 LGA released.\nWhat failed: Gauging Device.\nHow failed: Failed to Operate.\nReported failure causes: Freezing.\nReported result: Spillage, Material Entered Waterway/Storm Sewer, Vapor(Gas) Dispersion.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":723}