{"operation":"document","citation":"PHMSA Hazmat Incident E-2008030191","title":"PHMSA Hazmat Incident E-2008030191 — HYDROGEN, COMPRESSED — MIDDLEBURY, CT","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2008-02-12","summary":"Serious reporter-submitted hazardous materials transportation incident on 2008-02-12 in MIDDLEBURY, CT.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2008030191.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2008030191.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2008030191","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=T47QlPYZi06L2pGiMlhDgw%3D%3D","body":"PHMSA hazardous materials incident report E-2008030191.\nIncident date: 2008-02-12.\nLocation: MIDDLEBURY, CT.\nMode: Highway.\nCarrier/reporter: Linde Inc.\nShipper: Linde Inc.\nMaterials: UN1049; HYDROGEN, COMPRESSED; hazard class 2.1; 6.93465 GCF released.\nWhat failed: Valve Stem.\nHow failed: Cracked.\nReported failure causes: Vehicular Crash or Accident Damage.\nReported result: Vapor(Gas) Dispersion.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":684}