# PHMSA Hazmat Incident E-2012090074 — ACETONE — SANTA FE SPRINGS, CA

- **operation:** document
- **citation:** PHMSA Hazmat Incident E-2012090074
- **title:** PHMSA Hazmat Incident E-2012090074 — ACETONE — SANTA FE SPRINGS, CA
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** Not available
- **effective on:** 2012-08-13
- **summary:** Serious reporter-submitted hazardous materials transportation incident on 2012-08-13 in SANTA FE SPRINGS, CA.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2012090074.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2012090074.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2012090074
- **source url:** https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=f558bxtJr%2FpVm4FzEL61Dg%3D%3D
**body:**

PHMSA hazardous materials incident report E-2012090074.
Incident date: 2012-08-13.
Location: SANTA FE SPRINGS, CA.
Mode: Highway.
Carrier/reporter: Univar USA.
Shipper: Univar USA.
Materials: UN1090; ACETONE; hazard class 3; 900 LGA released.
What failed: High Level Sensor.
How failed: Failed to Operate.
Reported failure causes: Human Error.
Reported result: Spillage.
Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.
- **truncated:** false
- **body characters:** 654