{"operation":"document","citation":"PHMSA Hazmat Incident E-2016050147","title":"PHMSA Hazmat Incident E-2016050147 — ORGANIC PEROXIDE TYPE F, LIQUID — CHESTER SPRINGS, PA","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2016-04-11","summary":"Serious reporter-submitted hazardous materials transportation incident on 2016-04-11 in CHESTER SPRINGS, PA.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2016050147.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2016050147.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2016050147","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=dPl4F35NUhoXGMUpY31aQQ%3D%3D","body":"PHMSA hazardous materials incident report E-2016050147.\nIncident date: 2016-04-11.\nLocation: CHESTER SPRINGS, PA.\nMode: Highway.\nCarrier/reporter: FedEx Freight.\nShipper: Zee Co.\nMaterials: UN3109; ORGANIC PEROXIDE TYPE F, LIQUID; hazard class 5.2; 265 LGA released.\nWhat failed: Body.\nHow failed: Punctured.\nReported failure causes: Forklift Accident.\nReported result: Spillage.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":663}