{"operation":"document","citation":"PHMSA Hazmat Incident E-2019060197","title":"PHMSA Hazmat Incident E-2019060197 — ARGON, REFRIGERATED LIQUID (CRYOGENIC LIQUID) — BUFFALO, KS","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2019-05-07","summary":"Serious reporter-submitted hazardous materials transportation incident on 2019-05-07 in BUFFALO, KS.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2019060197.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2019060197.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2019060197","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=XV5vn8C2dyUNVNoBNEZeIA%3D%3D","body":"PHMSA hazardous materials incident report E-2019060197.\nIncident date: 2019-05-07.\nLocation: BUFFALO, KS.\nMode: Rail.\nCarrier/reporter: UNION PACIFIC RAILROAD COMPANY.\nShipper: Air Liquide AMERICA.\nMaterials: UN1951; ARGON, REFRIGERATED LIQUID (CRYOGENIC LIQUID); hazard class 2.2; 50 LGA released.\nWhat failed: Piping or Fittings; Piping or Fittings.\nHow failed: Leaked; Torn Off or Damaged.\nReported failure causes: Broken Component or Device; Derailment.\nReported result: Spillage, Vapor(Gas) Dispersion.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":791}