# PHMSA Hazmat Incident E-2023120219 — SULFUR, MOLTEN — LIVINGSTON, KY

- **operation:** document
- **citation:** PHMSA Hazmat Incident E-2023120219
- **title:** PHMSA Hazmat Incident E-2023120219 — SULFUR, MOLTEN — LIVINGSTON, KY
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** Not available
- **effective on:** 2023-11-22
- **summary:** Serious reporter-submitted hazardous materials transportation incident on 2023-11-22 in LIVINGSTON, KY.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2023120219.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2023120219.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-e-2023120219
- **source url:** https://portalpublic.phmsa.dot.gov/analytics/saw.dll?Portal?PortalPath=/shared/Public%20Website%20Pages/_portal/Hazmat%20Incident%20Report%20Search
**body:**

PHMSA hazardous materials incident report E-2023120219.
Incident date: 2023-11-22.
Location: LIVINGSTON, KY.
Mode: Rail.
Carrier/reporter: CSX TRANSPORTATION, INC..
Shipper: Imperial Oil.
Materials: UN2448; SULFUR, MOLTEN; hazard class 4.1; 9564 LGA released | UN2448; SULFUR, MOLTEN; hazard class 4.1; 9892.875 LGA released.
What failed: Tank Head.
How failed: Punctured.
Reported failure causes: Derailment.
Reported result: Spillage, Fire, Environmental Damage.
Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.
- **truncated:** false
- **body characters:** 748