{"operation":"document","citation":"PHMSA Hazmat Incident I-1990110119","title":"PHMSA Hazmat Incident I-1990110119 — OXYGEN, REFRIGERATED LIQUID (CRYOGENIC LIQUID) — JEANNETTE, PA","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"1990-10-23","summary":"Serious reporter-submitted hazardous materials transportation incident on 1990-10-23 in JEANNETTE, PA.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-1990110119.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-1990110119.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-1990110119","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=rHWUrAaZZ4EKnwF8ixGi5A%3D%3D","body":"PHMSA hazardous materials incident report I-1990110119.\nIncident date: 1990-10-23.\nLocation: JEANNETTE, PA.\nMode: Highway.\nCarrier/reporter: LIQUID CARBONICS CORP.\nShipper: LIQUID CARBONICS CORP.\nMaterials: UN1073; OXYGEN, REFRIGERATED LIQUID (CRYOGENIC LIQUID); hazard class 2.2; 600 LGA released.\nWhat failed: Auxiliary Valve; Bottom Outlet Valve; Piping or Fittings.\nHow failed: Cracked.\nReported failure causes: Rollover Accident; Vehicular Crash or Accident Damage.\nReported result: Spillage, No Release.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":793}