{"operation":"document","citation":"PHMSA Hazmat Incident I-2009120098","title":"PHMSA Hazmat Incident I-2009120098 — OXYGEN, REFRIGERATED LIQUID (CRYOGENIC LIQUID) — VERNON, CA","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2009-11-11","summary":"Serious reporter-submitted hazardous materials transportation incident on 2009-11-11 in VERNON, CA.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2009120098.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2009120098.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2009120098","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=sS04ExYKNH1D%2FOGcOYoihw%3D%3D","body":"PHMSA hazardous materials incident report I-2009120098.\nIncident date: 2009-11-11.\nLocation: VERNON, CA.\nMode: Highway.\nCarrier/reporter: CRYOGENIC TRANSPORTATION INC.\nShipper: MATHESON TRIGAS.\nMaterials: UN1073; OXYGEN, REFRIGERATED LIQUID (CRYOGENIC LIQUID); hazard class 2.2; 2000 LGA released.\nWhat failed: Bottom Outlet Valve.\nHow failed: Leaked.\nReported failure causes: Loose Closure, Component, or Device.\nReported result: Vapor(Gas) Dispersion.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":737}