# PHMSA Hazmat Incident I-2014100537 — ORGANIC PEROXIDE TYPE F, LIQUID — BRIDGEPORT, CA

- **operation:** document
- **citation:** PHMSA Hazmat Incident I-2014100537
- **title:** PHMSA Hazmat Incident I-2014100537 — ORGANIC PEROXIDE TYPE F, LIQUID — BRIDGEPORT, CA
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** Not available
- **effective on:** 2014-07-26
- **summary:** Serious reporter-submitted hazardous materials transportation incident on 2014-07-26 in BRIDGEPORT, CA.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2014100537.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2014100537.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2014100537
- **source url:** https://portalpublic.phmsa.dot.gov/analytics/saw.dll?Portal?PortalPath=/shared/Public%20Website%20Pages/_portal/Hazmat%20Incident%20Report%20Search
**body:**

PHMSA hazardous materials incident report I-2014100537.
Incident date: 2014-07-26.
Location: BRIDGEPORT, CA.
Mode: Highway.
Carrier/reporter: MOUNTAIN VALLEY EXPRESS CO INC.
Shipper: ECOLAB.
Materials: UN3109; ORGANIC PEROXIDE TYPE F, LIQUID; hazard class 5.2; 30 LGA released.
What failed: Body.
How failed: Cracked; Leaked.
Reported failure causes: Inadequate Blocking and Bracing.
Reported result: Spillage, Material Entered Waterway/Storm Sewer.