{"operation":"document","citation":"PHMSA Hazmat Incident I-2015110719","title":"PHMSA Hazmat Incident I-2015110719 — BATTERIES, WET, FILLED WITH ACID, ELECTRIC STORAGE — CREVE COEUR, MO","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2015-09-29","summary":"Serious reporter-submitted hazardous materials transportation incident on 2015-09-29 in CREVE COEUR, MO.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2015110719.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2015110719.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2015110719","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=hDClv5UmOv2xD4CiqutH7g%3D%3D","body":"PHMSA hazardous materials incident report I-2015110719.\nIncident date: 2015-09-29.\nLocation: CREVE COEUR, MO.\nMode: Highway.\nCarrier/reporter: ELECTRO BATTERY MANUFACTURING CO INC.\nShipper: EAST PENN MANUFACTURING CO..\nMaterials: UN2794; BATTERIES, WET, FILLED WITH ACID, ELECTRIC STORAGE; hazard class 8; 0 SLB released | UN2796; BATTERY FLUID, ACID; hazard class 8; 8.375 LGA released.\nWhat failed: Body / Vent.\nHow failed: Cracked / Leaked.\nReported failure causes: Inadequate Accident Damage Protection / Rollover Accident.\nReported result: Spillage.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":838}