# PHMSA Hazmat Incident I-2018100126 — FERRIC CHLORIDE, SOLUTION — Mobile, AL

- **operation:** document
- **citation:** PHMSA Hazmat Incident I-2018100126
- **title:** PHMSA Hazmat Incident I-2018100126 — FERRIC CHLORIDE, SOLUTION — Mobile, AL
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** Not available
- **effective on:** 2018-09-14
- **summary:** Serious reporter-submitted hazardous materials transportation incident on 2018-09-14 in Mobile, AL.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2018100126.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2018100126.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-hazmat-incident-i-2018100126
- **source url:** https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=vCHEfJShvtqxRmz6YU6hew%3D%3D
**body:**

PHMSA hazardous materials incident report I-2018100126.
Incident date: 2018-09-14.
Location: Mobile, AL.
Mode: Highway.
Carrier/reporter: UPS FREIGHT.
Shipper: HARCROS CHEMICALS INC.
Materials: UN2582; FERRIC CHLORIDE, SOLUTION; hazard class 8; 250 LGA released.
What failed: Body.
How failed: Punctured.
Reported failure causes: Inadequate Blocking and Bracing.
Reported result: Spillage.
Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.
- **truncated:** false
- **body characters:** 673