{"operation":"document","citation":"PHMSA Hazmat Incident X-2014040343","title":"PHMSA Hazmat Incident X-2014040343 — ARGON, REFRIGERATED LIQUID (CRYOGENIC LIQUID) — Enid, OK","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2014-03-30","summary":"Serious reporter-submitted hazardous materials transportation incident on 2014-03-30 in Enid, OK.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2014040343.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2014040343.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2014040343","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=qp6hOTunHB4CK9xvRGrzKA%3D%3D","body":"PHMSA hazardous materials incident report X-2014040343.\nIncident date: 2014-03-30.\nLocation: Enid, OK.\nMode: Rail.\nCarrier/reporter: Union Pacific Railroad.\nShipper: Praxair, Inc..\nMaterials: UN1951; ARGON, REFRIGERATED LIQUID (CRYOGENIC LIQUID); hazard class 2.2; 0.625 LGA released.\nWhat failed: Auxiliary Valve.\nHow failed: Leaked.\nReported failure causes: Broken Component or Device.\nReported result: Spillage.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":698}