{"operation":"document","citation":"PHMSA Hazmat Incident X-2015030178","title":"PHMSA Hazmat Incident X-2015030178 — CHLORINE — LEESVILLE, LA","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":null,"effective_on":"2015-03-02","summary":"Serious reporter-submitted hazardous materials transportation incident on 2015-03-02 in LEESVILLE, LA.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2015030178.json","markdown":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2015030178.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-hazmat-incident-x-2015030178","source_url":"https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=4qQSxMfikvCY9YY5lZo%2FJw%3D%3D","body":"PHMSA hazardous materials incident report X-2015030178.\nIncident date: 2015-03-02.\nLocation: LEESVILLE, LA.\nMode: Rail.\nCarrier/reporter: Kansas City Southern Railroad.\nShipper: Formosa Plastics.\nMaterials: UN1017; CHLORINE; hazard class 2.3; 0.26736 GCF released.\nWhat failed: Liquid Valve.\nHow failed: Leaked.\nReported failure causes: Improper Preparation for Transportation; Human Error.\nReported result: Spillage.\nReporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.","truncated":false,"body_characters":701}