# DCP MIDSTREAM, LP — Type R reporting-regulated gas gathering — incident on 2025-01-19

- **operation:** document
- **citation:** PHMSA Report 20250003
- **title:** DCP MIDSTREAM, LP — Type R reporting-regulated gas gathering — incident on 2025-01-19
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2025-02-18
- **effective on:** 2025-01-19
- **summary:** Type R reporting-regulated gas gathering incident in Not Within a Municipality, SEWARD County, KS. Reported cause: CORROSION FAILURE. Reported consequences: 0 fatalities, 0 injuries, 23440 NATURAL GAS released, $12,500 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-incident-00fb30cb86bbbc00bcb46036.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-incident-00fb30cb86bbbc00bcb46036.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-incident-00fb30cb86bbbc00bcb46036
- **source url:** https://data.transportation.gov/api/views/27nc-rsge/files/021f4773-ebc0-4abc-8628-9321af069f69?download=true&filename=Type%20R%20Reporting-Regulated%20Gas%20Gathering%20May%202022%20to%20Present.zip
**body:**

Type R reporting-regulated gas gathering incident in Not Within a Municipality, SEWARD County, KS. Reported cause: CORROSION FAILURE. Reported consequences: 0 fatalities, 0 injuries, 23440 NATURAL GAS released, $12,500 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.

Report number: 20250003.

Operator ID: 31130.

Reported incident date: 1/19/2025 8:40.

Cause detail: INTERNAL CORROSION

Cause detail: ON JANUARY 19, 2025, AT APPROXIMATELY 8:40AM CST THE 16-03-121-01-16", A TYPE R PIPELINE, EXPERIENCED A FAILURE. RELEASE VOLUME DETERMINED TO EXCEED REPORTING THRESHOLD AND NRC NOTIFICATION MADE ACCORDINGLY. PIPE SAMPLES HAVE BEEN SENT TO A LABORATORY FOR ANALYSIS TO DETERMINE THE CAUSE. UPDATE - 5/16/2025 - NEW INFORMATION FOLLOWING THE INCIDENT A PIPE SAMPLE WAS SENT FOR LAB ANALYSIS; THE LAB ANALYSIS INDICATED THE PIPE IS 25,000 SMYS. RECORDS WERE UPDATED ACCORDINGLY, AND THE LINE HAS BEEN RECLASSIFIED AS TYPE C BASED ON OPERATING AT GREATER THAN 20 PERCENT OF SMYS. UPDATE - 5/19/2025 - AT REQUEST OF PHMSA INFORMATION IN PART G UPDATED TO REFLECT LAB ANALYSIS FINDING OF INTERNAL CORROSION AS CAUSE.
- **truncated:** false
- **body characters:** 1262