{"operation":"document","citation":"PHMSA Report 20130057","title":"FLORIDA GAS TRANSMISSION CO — Gas transmission and gathering — incident on 2013-05-29","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2013-06-27","effective_on":"2013-05-29","summary":"Gas transmission and gathering incident in TAMPA, HILLSBOROUGH County, FL. Reported cause: NATURAL FORCE DAMAGE. Reported consequences: 0 fatalities, 0 injuries, 1443.2 NATURAL GAS released, $130,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-incident-03001cb74bf6cd875b62c4c6.json","markdown":"https://regulus.evalyn.ai/document/phmsa-incident-03001cb74bf6cd875b62c4c6.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-incident-03001cb74bf6cd875b62c4c6","source_url":"https://data.transportation.gov/api/views/27nc-rsge/files/2b05c2d8-d14a-4c56-ac1c-7d23a4bc31c8?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%20January%202010%20to%20present.zip","body":"Gas transmission and gathering incident in TAMPA, HILLSBOROUGH County, FL. Reported cause: NATURAL FORCE DAMAGE. Reported consequences: 0 fatalities, 0 injuries, 1443.2 NATURAL GAS released, $130,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.\n\nReport number: 20130057.\n\nOperator ID: 5304.\n\nReported incident date: 5/29/2013 23:26.\n\nLocation detail: 3551+05\n\nCause detail: OTHER NATURAL FORCE DAMAGE\n\nCause detail: AFTER DISCUSSIONS WITH THE PHMSA SOUTHERN REGION, THIS SUPPLEMENTAL FINAL REPORT IS SUBMITTED TO CHANGE THE CAUSE FROM G8 - OTHER INCIDENT CAUSE, TO G2 - OTHER NATURAL FORCE DAMAGE. THIS IS AN INTERACTING FAILURE. THERE WERE TWO CAUSES. LIGHTNING STRIKE ON A THIRD PARTY GROUNDING ROD. A LEAK OCCURRED ON WEDNESDAY MAY 29, 2013 ON THE ST. PETE LATERAL BETWEEN MLV 24-70 AND MLV 24-8. AFTER THE LEAK WAS IDENTIFIED, THIS SECTION OF PIPE WAS ISOLATED AND BLOWNDOWN. THE AFFECTED PIPE HAD A 7.5' SECTION CUT-OUT AND REPLACED ON JUNE 1, 2013.\n\nPHMSA trend classification: significant incident, not serious.\n\nPHMSA standardized cause: NATURAL FORCE DAMAGE — OTHER NATURAL FORCE DAMAGE.\n\nPHMSA indexed costs: $146,972 reported total cost, $80,978.081 in 1984 dollars, $182,460.318 in current-year dollars.\n\nPHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.","truncated":false,"body_characters":1541}