# NATURAL GAS PIPELINE CO OF AMERICA — Gas transmission and gathering — incident on 1994-08-10

- **operation:** document
- **citation:** PHMSA Report 19940180
- **title:** NATURAL GAS PIPELINE CO OF AMERICA — Gas transmission and gathering — incident on 1994-08-10
- **source type:** incident
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 1994-09-13
- **effective on:** 1994-08-10
- **summary:** Gas transmission and gathering incident in LA. Reported cause: CORROSION. Reported consequences: 0 fatalities, 0 injuries, $226,012 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-incident-33e8ec412fe75cab1bb00477.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-incident-33e8ec412fe75cab1bb00477.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-incident-33e8ec412fe75cab1bb00477
- **source url:** https://data.transportation.gov/api/views/27nc-rsge/files/bea0164f-672a-475e-986b-8e45e9634dbf?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%20mid%201984%20to%202001.zip
**body:**

Gas transmission and gathering incident in LA. Reported cause: CORROSION. Reported consequences: 0 fatalities, 0 injuries, $226,012 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.

Report number: 19940180.

Operator ID: 13120.

Reported incident date: 19940810.

Location detail: INTERNALLY

Location detail: LOCALIZED PITTING

Cause detail: PENDING INVESTIGATION. THE AFFECTED PIPE SECTION IS ISOLATED. REPAIRS ANDFURTHER INVESTIGATION ARE NOT COMPLETE. SUPPLEMENTAL REPORT 3/21/95 INDICATESTHAT XRAY CONFIRMED INTERNAL CORROSION. LOCALIZED INTERNAL PITTING SHOWN BYXRAY. INSTALLED LEAK CLAMP.

PHMSA trend classification: significant incident, not serious.

PHMSA standardized cause: CORROSION — INTERNAL.

PHMSA indexed costs: $226,012 reported total cost, $169,235.883 in 1984 dollars, $416,775.896 in current-year dollars.

PHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.
- **truncated:** false
- **body characters:** 1150