{"operation":"document","citation":"PHMSA Report 20210055","title":"KINETICA ENERGY EXPRESS LLC — Gas transmission and gathering — incident on 2021-06-24","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2021-07-01","effective_on":"2021-06-24","summary":"Gas transmission and gathering incident. Reported cause: OTHER OUTSIDE FORCE DAMAGE. Reported consequences: 0 fatalities, 0 injuries, 25 NATURAL GAS released, $5,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: not significant, not serious.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-incident-8f35d03249b1f9884b246be1.json","markdown":"https://regulus.evalyn.ai/document/phmsa-incident-8f35d03249b1f9884b246be1.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-incident-8f35d03249b1f9884b246be1","source_url":"https://data.transportation.gov/api/views/27nc-rsge/files/2b05c2d8-d14a-4c56-ac1c-7d23a4bc31c8?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%20January%202010%20to%20present.zip","body":"Gas transmission and gathering incident. Reported cause: OTHER OUTSIDE FORCE DAMAGE. Reported consequences: 0 fatalities, 0 injuries, 25 NATURAL GAS released, $5,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.\n\nReport number: 20210055.\n\nOperator ID: 38987.\n\nReported incident date: 6/24/2021 16:15.\n\nCause detail: ROUTINE OR NORMAL FISHING OR OTHER MARITIME ACTIVITY NOT ENGAGED IN EXCAVATION\n\nCause detail: NOTIFIED BY USCG ON 6/25/2021. LEAK CONFIRMED BY HELICOPTER OVERFLIGHT ON 6/26/2021. DIVE VESSEL DISPATCHED ON 6/26/2021. DIVERS FOUND A CRACKED 1/2\" TUBING ON A 12\" SUBSEA VALVE OPERATOR. CLOSED ISOLATION VALVE TO STOP LEAK. ASSUMED TO BE CAUSED BY OUTSIDE FORCES.\n\nPHMSA trend classification: not significant, not serious.\n\nPHMSA standardized cause: OTHER OUTSIDE FORCE DAMAGE — FISHING OR MARITIME ACTIVITY.\n\nPHMSA indexed costs: $80,100 reported total cost, $35,953.529 in 1984 dollars, $88,461.452 in current-year dollars.\n\nPHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.","truncated":false,"body_characters":1262}