{"operation":"document","citation":"PHMSA Report 20150021","title":"ATLANTA GAS LIGHT CO — Gas transmission and gathering — incident on 2015-01-17","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2015-02-15","effective_on":"2015-01-17","summary":"Gas transmission and gathering incident in RIVERDALE, CLAYTON County, GA. Reported cause: EQUIPMENT FAILURE. Reported consequences: 0 fatalities, 0 injuries, 245 NATURAL GAS released, $312,794 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-incident-d71839107044369e82b7f0ed.json","markdown":"https://regulus.evalyn.ai/document/phmsa-incident-d71839107044369e82b7f0ed.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-incident-d71839107044369e82b7f0ed","source_url":"https://data.transportation.gov/api/views/27nc-rsge/files/2b05c2d8-d14a-4c56-ac1c-7d23a4bc31c8?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%20January%202010%20to%20present.zip","body":"Gas transmission and gathering incident in RIVERDALE, CLAYTON County, GA. Reported cause: EQUIPMENT FAILURE. Reported consequences: 0 fatalities, 0 injuries, 245 NATURAL GAS released, $312,794 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.\n\nReport number: 20150021.\n\nOperator ID: 792.\n\nReported incident date: 1/17/2015 10:50.\n\nLocation detail: 640 GA HWY 13\n\nCause detail: NON-THREADED CONNECTION FAILURE\n\nCause detail: A LEAK CALL WAS RECEIVED AT THE COMPANY'S CALL CENTER WHERE UPON INVESTIGATION A CRACK WAS DISCOVERED IN A 30-INCH WELD-OVER FITTING NEAR THE INTERSECTION OF WHERE THE FITTING IS WELDED TO THE PIPE. APPARENT CAUSE IS IDENTIFIED IN SECTION G6.\n\nPHMSA trend classification: significant incident, not serious.\n\nPHMSA standardized cause: EQUIPMENT FAILURE — NON-THREADED CONNECTION FAILURE.\n\nPHMSA indexed costs: $322,077 reported total cost, $163,909.135 in 1984 dollars, $397,378.658 in current-year dollars.\n\nPHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.","truncated":false,"body_characters":1251}