{"operation":"document","citation":"PHMSA Report 20050053","title":"CROSSTEX MISSISSIPPI PIPELINE LP — Gas transmission and gathering — incident on 2005-04-18","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2005-05-17","effective_on":"2005-04-18","summary":"Gas transmission and gathering incident in WARREN, WARREN County, MS. Reported cause: 14. Reported consequences: 0 fatalities, 0 injuries, $1,000,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-incident-db0e424b20cbf30bd91ad05d.json","markdown":"https://regulus.evalyn.ai/document/phmsa-incident-db0e424b20cbf30bd91ad05d.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-incident-db0e424b20cbf30bd91ad05d","source_url":"https://data.transportation.gov/api/views/27nc-rsge/files/3f48859a-5658-4f64-acf0-e33e632af625?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%202002%20to%20December%202009.zip","body":"Gas transmission and gathering incident in WARREN, WARREN County, MS. Reported cause: 14. Reported consequences: 0 fatalities, 0 injuries, $1,000,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.\n\nReport number: 20050053.\n\nOperator ID: 31880.\n\nReported incident date: 4/18/2005.\n\nCause detail: BODY OF PIPE\n\nCause detail: AREA GROUND SHIFT DUE TO HEAVY RAINS AND FORCES CAUSING PIPELINE TO WRINKLE AND BEND WHICH RESULTED IN A SMALL CRACK TO THE PIPE (APPROXIMATELY 1 INCH OPENING). UPDATED BY PHMSA ON 12/4/2015 PER OPERATOR'S MARK UP (PART C, QUESTION 5 - YEAR THE PIPE OR COMPONENT WHICH FAILED WAS INSTALLED).\n\nPHMSA trend classification: significant incident, not serious.\n\nPHMSA standardized cause: MATERIAL FAILURE OF PIPE OR WELD — BODY OF PIPE.\n\nPHMSA indexed costs: $1,000,000 reported total cost, $455,594.002 in 1984 dollars, $559,400.231 in current-year dollars.\n\nPHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.","truncated":false,"body_characters":1200}