- **summary:** Gas transmission and gathering incident in SHELBYVILLE, SHELBY County, IN. Reported cause: 19. Reported consequences: 0 fatalities, 0 injuries, $131,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-incident-e95a7ee2a86fe5051084a943.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-incident-e95a7ee2a86fe5051084a943.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-incident-e95a7ee2a86fe5051084a943
- **source url:** https://data.transportation.gov/api/views/27nc-rsge/files/3f48859a-5658-4f64-acf0-e33e632af625?download=true&filename=Gas%20Transmission%20%26%20Gathering%20Incident%20Data%20-%202002%20to%20December%202009.zip
**body:**

Gas transmission and gathering incident in SHELBYVILLE, SHELBY County, IN. Reported cause: 19. Reported consequences: 0 fatalities, 0 injuries, $131,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.

Report number: 20020076.

Operator ID: 405.

Reported incident date: 9/9/2002.

Cause detail: PIPE SEAM WELD

Cause detail: A SMALL LEAK WAS DISCOVERED FOLLOWING AN AERIAL PATROL OVER AN AREA OF DEAD VEGETATION. UPON FURTHER INVESTIGATION, A NON-FUSION CRACK 1/4" LONG IN THE LONGITUDINAL SEAM WAS FOUND.

PHMSA trend classification: significant incident, not serious.

PHMSA standardized cause: MATERIAL FAILURE OF PIPE OR WELD — PIPE SEAM.

PHMSA indexed costs: $131,000 reported total cost, $111,680.091 in 1984 dollars, $173,218.996 in current-year dollars.

PHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.