{"operation":"document","citation":"PHMSA Report 20100220","title":"ENTERPRISE PRODUCTS OPERATING LLC — Hazardous liquid — incident on 2010-08-27","source_type":"incident","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2010-10-07","effective_on":"2010-08-27","summary":"Hazardous liquid incident in GILBOA, SCHOHARIE County, NY. Reported cause: MATERIAL FAILURE OF PIPE OR WELD. Reported consequences: 0 fatalities, 0 injuries, 3283 HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBIENT CONDITIONS released, $1,441,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings. PHMSA trend classification: significant incident, not serious.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-incident-f848e0cf8a694bb7f24667c8.json","markdown":"https://regulus.evalyn.ai/document/phmsa-incident-f848e0cf8a694bb7f24667c8.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-incident-f848e0cf8a694bb7f24667c8","source_url":"https://data.transportation.gov/api/views/27nc-rsge/files/1d547e17-2be1-4a32-9958-a1d5a946ade9?download=true&filename=Hazardous%20Liquid%20Accident%20Data%20-%20January%202010%20to%20present.zip","body":"Hazardous liquid incident in GILBOA, SCHOHARIE County, NY. Reported cause: MATERIAL FAILURE OF PIPE OR WELD. Reported consequences: 0 fatalities, 0 injuries, 3283 HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBIENT CONDITIONS released, $1,441,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.\n\nReport number: 20100220.\n\nOperator ID: 31618.\n\nReported incident date: 8/27/2010 16:30.\n\nLocation detail: MP 133.87\n\nCause detail: ENVIRONMENTAL CRACKING-RELATED\n\nCause detail: 5/12/2011-THE FAILURE OCCURRED AS A CIRCUMFERENTIAL LEAK THAT ORIGINATED AT A CIRCUMFERENTIALLY-ORIENTED STRESS CORROSION CRACK (SCC) ADJACENT TO THE THE TOE OF A GIRTH WELD ON THE UPSTREAM PIPE JOINT.\n\nPHMSA trend classification: significant incident, not serious.\n\nPHMSA standardized cause: MATERIAL FAILURE OF PIPE OR WELD — ENVIRONMENTAL CRACKING-RELATED.\n\nPHMSA indexed costs: $1,811,756 reported total cost, $991,327.535 in 1984 dollars, $2,441,334.622 in current-year dollars.\n\nPHMSA trend flags, standardized causes, and indexed costs are analytical fields added to operator-reported incident data. They do not represent final agency causal findings.","truncated":false,"body_characters":1291}