# Western Poly Drums, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 00-0024
- **title:** Western Poly Drums, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2000-03-15
- **effective on:** Not available
- **summary:** 00-0024 response to Western Poly Drums, Inc. concerning 178.604.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0024.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0024.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0024
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2000/000024.pdf
**body:**

<<<PAGE 1>>>

..
U.S.Department
of Transportation
400 Seventh Street, S.W.
Washington, D.C.
20590
MAR 1 5 2000
Mr. Floyd A. Whitney
President
Ref. No: 00-0024
Western Poly Drums, Inc.
8727 Rochester Ave.
Rancho Cucamonga, CA 91729-4200
Dear Mr. Whitney:
This is in response to your letter of January 25, 2000, requesting clarification of the requirements for
leakproof testing of non-bulk packagings under the Hazardous Materials Regulations (HMR; 49 CFR
parts 171-180). Specifically you ask whether you may follow the methods outlined in Appendix B to
Part 178--Alternative Leakproofness Test Methods, as an alternative to the testing procedure required
by § 178.604.
The answer is yes. As stated in § 178.604(d) Test method, "other methods, at least equally effective,
may be used in accordance with appendix B of this part."
I hope this information is helpful.
Sincerely,
Delmer F. Billings
Chief, Standards Development
Office of Hazardous Materials Standards
000024

<<<PAGE 2>>>

POLY
FIBRE
STEEL
WESTERN
POLY
WHY NOT PLACE YOUR NEXT ORDER ON-LINE?
www.WesternPoly.com
DRUMS, INC.
A COMPLETE LINE OF U.N. CONTAINERS & TANKS
Hattie L. Mitchell
Research and Special Program
U.S. Department of Transportation
400 Seventh Street, S.W
Washington, D.C. 20590
January 10, 2000
Subject: Steel drum re-con leek proof test
Dear, Hattie L. Mitchell
Western Poly Drums, Inc. is going into re-con steel drums business.
As I understand CFR 49, #173.28 & 178.604 (d) leak proof test I can use
Ne are also going to have the drums third party tested each year
Appendix B (2) and (3) is this correct
Please let me know as soon as possible if I am correct.
Floyd A Whitney
President
8727 ROCHESTER AVE., RANCHO CUCAMONGA, CA 91729-4200 (909) 466-9927 FAX 945-3075
-
- **truncated:** false