# Alaska Airlines — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 00-0206
- **title:** Alaska Airlines — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2000-12-13
- **effective on:** Not available
- **summary:** 00-0206 response to Alaska Airlines concerning 175.10.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0206.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0206.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0206
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2000/000206.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh St., S.W.
Washington, D.C. 20590
Research and
DEC 1 3 2000
Special Programs
Administration
Ms. Marilyn Dirkx .
Reference No.: 00-0206
Manager, Dangerous Goods Compliance
Alaska Airlines
Box 68900
Seattle, WA 98168-0900
Dear Ms. Dirkx:
This is in response to your July 24, 2000 letter concerning certain carbon dioxide cylinders that
are used in a medical device to administer needle-free injections. Specifically, you asked if the
cylinders may be carried on board a passenger aircraft in checked or carry-on luggage under the
exception in § 175.10(a)(4)(i), 175.10(a)(18) or § 175.10(a)(25) of the Hazardous Materials
Regulations (49 CFR Parts 171-180). I apologize for the delay and any inconvenience it may
have caused.
Based on our review of information provided by a manufacturer of these medical devices, it is
our opinion that the cylinders may be carried aboard passenger-carrying aircraft in checked or
carry-on luggage under the provision in § 175.10(a)(4)(i). The devices do not qualify for the
exceptions in §§ 175.10(a)(18) and 175.10(a)(25). The Federal Aviation Administration is in
agreement with this position.
Should you have further questions, please contact this office.
Sincerely,
idward T. Mazzull
Director, Office of Hazardous Materials Standards

<<<PAGE 2>>>

JUL. 24.2000
10: 35AM
ALASKA AIRLINES
NO.169 P.2/2
-
Allayka
Airlines
corbin
U.S. Department of Transportation
8 175.10
Research and Special Programs Administration
Office of Hazardous Materials Standards
06 - 0206
400 Seventh St SW
Washington, DC 20590
Attn: Mr. Ed Mazzullo
July 24, 2000
Dear Mr. Mazzullo:
Recently, a passenger attempted to carry in his checked luggage two small
carbon dioxide cylinders used for administering medical injections. They were
discovered during CIX screening. (The CT, is an explosive detection x-ray!
system that has been instrumental in detecting undeclared hazardous materials.)
The screener advised the passenger that the çylinders could not be carried in
luggage, and the passenger was forced to remove them from his luggage. The
passenger, a physician, was very irritated, and stated that these small carbon
dioxide cylinders are very common and that people are carrying them around all
the time. According to the supervisor who responded to the call by the CIX
operator, the cylinders were smaller than theitype used in live vests that arę
approved for carriage by 49CFR 175.10(a) (25).
My question to you is this: May small carbori dioxide cylinders used for the
administration of medical injections be cartied onboard or transported in
checked luggage as permitted in 175.10(a) (25), or 175.10(a)(18), or can they be
considered medicinal and allowed per 175.10(a)(4)(i)?
Thank you for your response.
Sincerely,
marily
Marilyn Dirlex
Manager, Dangerous Goods Compliance
Tel 206-431-7442
Fax 206-433-3225
BOX
68900 SEATILE WA
+8168-09001206-433-3200

<<<PAGE 3>>>

JUL. 24.2000
10: 35AM
ALASKA AIRLINES
1
NO. 169|
P.1/2
..i.
Fi==
To:
Mr. Ed Mazzullo
J.S. Department of Transportation
Research and Special Programs Administratior
Office of Hazardous Materials Standards
Fax number 202-366-3012
From: Marilyn Dirkx
Manager, Dangerous Goods Compliance
Alaska Airlines
Fax number 206-433-3225
Tel number 206-431-7442
Pages: 2 including this cover.

<<<PAGE 4>>>

Atten is the sen
ere. me the bale
I Do not see that this
intent per hat
then person and use
-
om A
1--
AcTina AÁfor HMS...
10-18-00

<<<PAGE 5>>>

# 11/02/00 T#U 11:40 FAX 803 620 6431
BIOJECT
Ø001
MEMORANDUM
BOJECT
-
To:
Gigi Corbin
U.S. Department of Transportation
RSPA/DHM-12/ Room 8422
400 Seventh Street, SW
FAX: (SO9) E2X 5002
WWW.BIOJECT.CCM
Washington, DC 20590-0001
From:
Jim Bonicatto
Date:
01 November 2000
Cc:
Tom Brooks
Subject:
Bioject Inc. Part No. 1C08010, 8 gram CO, Gas Cartridge(s)
mentioned 8 gram CO2 gas cartridge (cylinder) for use with the Biojector® Needle Free Injection
This memorandum along with the attached data (2 pages) serves to address the above
Management System.
The cylinders are filled with 8 grams of CO2 and sealed. Once sealed in an enclosed, constant
and attachments show the relationship of temperature and pressure. It must also be noted that
rolume, the gas pressure is related to the temperature of the environment. The following table
the minimum burst pressure of the cylinders is rated at over 6000 psi. This provides sufficient
margin for product delivered and stored at normal temperatures.
Summary of Pressure vs. Temperature:
Temperature (E)
32
Pressure (psi)
68
506
88
1071
831
140
3190
If there any further questions please feel free to contact myself (503) 639-7221 x417 or Tom
Brooks (X437).
Regards,
R&D Manager
Jim Bonicatto

<<<PAGE 6>>>

$ 11/02/00 THU 11:41 FAX 503 620 6431
BIOJECT
41003
iSi
INDUSTRIAL PRODUCTS
PRODUCT INFORMATION
STANDARDS ....
Product Range
FLLNG......H
-emmer EN. DIN, TUV, DOT, MOD, ES. MIL, FAA, TSO. ASTA. EMPA, DAN
Mutiply
Converton Foctors
• Carban Doxice (COa, Narogen (Na)
SURFACE TREATMENT... Eechroplated Zing, Super (high corsion resistant) Zac
MMI
MARKING...
Solact from toble below. Other sees, goses and filings on request.
Ink le1, Engraving or Printing to specticion
Nominal Weights
orcas
CopociTy
Water
Diameter
Body
• Overall
crOms
ml
Lengm
Neck datalis
8
10.5 & 12
10
10 & 1T.5
15
665
. 82,5
• 3/8°×24 UNF 1A
12
• 14
82.5
3.7 mm Die PLAW
21
82.5
3/8 x 24 UNFA
16
21
88.5
73mm CYa PLAIN
US gason
21
89,5
9.7 mm DkI PLAN
UX cotton
US thic cusco
29.57
Fres
16
32
38.5
8.9 mm Da PLAIN
ml
20.23 & 24
105
3/8° X24 UNF 1A/2A
28
40
40
760
1/2° x20 UNFlA
14.5 psi
= Conversic
28
3.5 mm Dia PlAIN
Bart
28,30 & 33
45
160
52
• 139
3/9° X2A UNFlA/
35 & 38
1/2 × 20 UNFA
45
178
FOR VARIOUS FLING DENSILES OF COZ
PRESSURE - TEMPERATURE
55 3 20
85
138
1/2 ×20 UNF TA
filing density = "Water copochy crad
Wt of COs (a)
75
103
163
189
1220 F A
81
86
115
1/25 × 20 UNF TA
120
145
1/2°=20 UNFIA
200-
210
198
10230UF 1A
(3180psh)
120° & 135°
210
176
171
1/2x20LNF1A
400
Maso
120, 735 & 150
215
300
1/2° = 20 UNF 1A
230°
350
226
1/2 × 20 UNFTA
450
275
300
1D,08s
290°
1/2° x 20 UNF lA
295
400
225
1/2° x20 UNF lA
915
440
215
1/2×20 UNF lA
330°
500
311
1/2° ×20 UNFA
345
525
375
1/2 ×20 UNF TA
450
600
265
1/2° ×20 UNF TA
460°
700
311
368
1/2 X2 UNFA
• DOT Approved.
Produet range may be updaled, Please check with us.
1/2 × 20 UME 1A
TEMPERATURÉ CCT → :
40 6c
80
120
180
Physical Characteristics
Odour
Carbon Dioxide (CO2)
Taste
•
Stightty pungent
Niltogen (N»
Fire hazard
Acidic/Biting
None
Toxicity
Non-lammable
None
Liquid density (20°C)
Mox. 0.5% V/V continuous
Nor-itammable
Incroncihe 1140 ana yan un-s
0.775 kg
Non-toxic

<<<PAGE 7>>>

11/02/00 THU 11:41 FAX 503 620
6431
BIOJECT
Q002
Carbon Dioxide
291
Iesap
Pressure
Voluzac
cu {t/1b
(Densityl
| lb/cu /t
Enthalpyan
Entropy=
E
Solid
Solid
Solid
paia
paig
Vagor
Liquid
Ilquid
Vapor
Liquid vapor
-6
276.3
+
.-2
285.8
261.6
295.7
271.1
0.3233
2
316.3
305.8
281.0
0.3010
0.3119
64. 62
193.0
63.63
63.96
194.9
193.9
* 316.01
315-99
0.6979
0. 7000
10.9691
315.95
0.9678
291.1
6
327.0
10
8
337.9
:
301.6
0,2805
0.2906
63.30
196.9
195. 8
315.92
0.7043 | 0.9654
0.7022 | 0.9666
312.3
349.0
323.2
0.2707
360.5
334.3
0.2523
0.2613
62.97
198.0
315.83
315.88
10.7085
0.7064
0.9642
62.50
200.0
198.9
315.760-7106
0.9629
315.68
0.7127 0.9603
10.9616
345.8
w N
369.6
357.5
0.2353
0.2436
61.99
61.69
315,50
315.59
0. 7169 | 0.9575
0.72+8
10.9589
409-
196
381.8
0.2273
394.3
0.2196
61.32
61:02
204.2
315.40
315.27
0.7190
0.7211/0.9547
0.9561
20
42I.9
407.2
0. 2122
60.32
60.67
21
$35.1
420-4
0,2050
206.3
205.2
315.13
314.96
0.7253
0.7232
0.9533
28
26
462.5
448.7
434.0
0.1980
461.9
417.8
0.I911
59.57
59.91
208.4
207.4
314.80
0.7275
0.9520
314.62
0.7297
0.9493
0.9507
476.6
0.1845
59.17
$ 30
Va
•32
490.8
490.8
476.1
0. 1783
58.78
210.6
209.S
314.42
314,19
0.7341
0.7319
0.9479
34
505.5
0. 1722
58.02
58.40
211.7
313.90
0. 7363
0.9465
and
36
520.5
sos, 8.
0.1663
214.0
212.8
313.58
0.9450
38
551.7
$36.0
521.3
0.1602
0.2482
0.1542
57.59
313.20
0. 7385
0.7407
0.9434
57. IZ
216.4
215.1
312.77
0.7429
0.9399
0.9417
567.7
553.0
537.0
0.1425
$6.70
LI
•44
584.0
569.3
0. 1372
56.29
217.4
311-76
312.23
0.7452
0.7475
0,9380
600.8
0.1273
0.1321
55.89
218.7
311.20
0.7598
0. 9360
46
617.8
586. 1
55.44
222.5
221.2
220.0
310.63
0. 7521
D.9340
310.05
0.7544
0.9321
SO
48
635.2
603.1
638,2
620.5
0. 1226
54.95
309.47
0.7568
0.9302
52
652.9
0.1138
0. 1281
53.91
54.43
54
671.2
223.7
308.90
0.7593
0. 9283
56
708.6
689.7
656.5
675,0
0.1095
$3. +5
226.4
225.0
308.32
0.7618
0.9264
713.2
693.9
0.1054
52.95
307.75
0. 7643
0.9227
0.9246
727.9
0. 09752
0. 1014
S1.81
52.37
227.7
62
767.7
747.6
230.6
229.1
307.13
306.49
D. 7694
0. 7668
0. 9187
0.9207
732.9
753.0
0.08999
0. 09372
51.17
66
64
788.3
773.6
49.78
50.47
233.5
232.0
305.03
305.78
0.7746
0. 7720
0.9166
304.22
0. 7773
0.9145
68
809.3
"то
852.7
830.8
794.6
838.0
816.1
0.08631
0.07894
0.08261
$9.03
236.7
235.1
303.35
0. 7801
0. 9123
47.62
48.39
302.45
0. 7830
0. 9100
72
74
875.0
238.3
301.52
0.7861
0.9053
0.9077
76
897.8
883.1
860.3
0.07535
0.06811
0. 07173
46.80
242.1
240.3
300.51
299.39
0.7894
0. 7930
O.9030
78
945.1
921.1
906-4
45.90
930.4
0.06013
0. 06411
44.94
244.3
298.10
0.7970
0.9006
82
80
969.5
979.3
954.8
42.67
43.90
248.9
246.4
296.57
0. 8013
0. 8982
294.75
0. 8060
0.892%
0. 8957
un i
84
1020
994.5
1031
1005
0.05171
0.05603
39.59
41.23
251.5
86
87.9 | 1071
1046
254.7
292.46
289.67
0. 8112
0.8170
0.3881
1056
0. 04711
0. 03423
29.21
37.03
272.7
259.0
285.64
0. 8249
0. 8737
0. 8821
272.70
0.8483
0. 8483
**Based on 0 for the perfect cryatal at absolute zero of temporature,
-459.67F (-273.15C)

<<<PAGE 8>>>

AUG-Ø1-2000 15:24
HMIC
P.Ø1/Ø1
•
TO: Tom Brooks
Date: Aug. 1, 2000
FAX: (503) 624-9002
RE: Product Specs for Biojector 2000 and similar devices
Send to:
Gigi Corbin
U.S. Department of Transportation
RSPA/DHM-12/ Room 8422
400 Seventh Street, SW
Washington, DC 20590-0001
(202) 366-4465
Thanks.
GIGI-
THAnKS FOR QOUR CALL; THIS IS THE
IntO TO Den @THE FAA.
175.10.41, Looks GooDs, I ALsO
THOUGHT 175,10. AiV WAS InTERESTING ALSO.
I'l be walting far our next
DISCUSSIOn, AS THIS IS CRITICAL TO OUR
Business.
THEs AGAIN -
Tom
TOTAL P.Ø1

<<<PAGE 9>>>

TO: Tom Brooks
Date: Aug. 1, 2000
FAX: (503) 624-9002
RE: Product Specs for Biojector 2000 and similar devices
Send to:
Gigi Corbin
U.S. Department of Transportation
RSPA/DHM-12/ Room 8422
400 Seventh Street, SW
Washington, DC 20590-0001
(202) 366-4465
Thanks.

<<<PAGE 10>>>

:
$ =F
***************-COMM. JOURNAL- ******************* DATE AUG-01-2000 ***** TIME 15:24 *** P.01
MODE = MEMORY TRANSMISSION
START-AUG-Ø1 15:23
END-AUG-Ø1 15:24
FILE NO.* 091
STN NO.
COM
ABER NO.
STATION NAME/TEL. NO.
PAGES DURATION
001
OK
915036249002
001/001 00:08'20"
-HMIC
-
********************************-2023653012
-***** -
-********
•
TO: Tom Brooks
Date: Aug. 1, 2000
FAX: (503) 624-9002
RE: Product Specs for Biojector 2000 and similar devices
Send to:
•
Gigi Corbin
RSPA/DHM-12/ Room 8422
U.S. Department of Transportation
400 Seventh Street, SW
Washington, DC 20590-0001
(202) 366-4465
Thanks.

<<<PAGE 11>>>

Welcome to the Future of Needle-free Technology
http://www.biojcct.com/
Welcome to the Future of Needle-free Technology
Download the
1999 Annual
• hila
Report
format. If you are unable to read pdf
The 1999 Annual Report is in pdf
files, then click on the Adobe Acrobat
logo, and download Adobe Acrobat
Reader.
UCIN
TUV
Get Acrobat® &
Reader d
What's New
150 G 5001
Bioject Closes $10 Million in Equity Financing
Go!
Commitment to Performance
Through the commitment of each employee, the Bioject team will deliver
requirements and raise community awareness of safe, effective, needle-free
quality products and responsive services which meet or exceed customer
injection technology.
healthcare industry threatening the well being of medical professionals and
Contaminated needlestick injuries take an enormous toll on today's
costing health care providers millions of dollars annually.
Now there is an effective needle-free drug delivery method for subcutaneous
and the subsequent spread of bloodborne pathogens. Because it is easy to
and intramuscular injections that prevents contaminated needlestick injuries
injections.
use and patient preferred, it marks a new standard of care for administering
The Biojector 2000 Needle-Free Injection Management System delivers
compressed carbon dioxide (CO,) as a safe power source to inject
medications parenterally without a needle. Instead, the Biojector uses
action effectively penetrates the skin and delivers the medication into the
medication through a micro-orifice within a fraction of a second. This delivery
patients's tissue.
cross-contamination with its unique, patented, disposable medication syringe.
The Biojector eliminates costly maintenance and the threat of
Once an injection is given, the needle-free syringe is discarded. Single-use
delivery for medical professionals, advancing the overall quality of healthcare.
Bioject syringes provide safe injections for patients and needle-free drug
1 of2
7/28/00 3:52 PM

<<<PAGE 12>>>

Welcome to, the Future of Needle-free Technology
http://www.bioject.com/
Send Comments About The Web Site To:
BROJECT
Call: 800.683.7221
www.Bioject.com
H6S2H
Customer Service
7620 SW Bridgeport Road
customerservice@Bioject.Com
E-Mail:
Portland OR 97224
Injection Management Systems are trademarks of Bioject Inc. Last
Biojector® is a registered trademark, and Bioject and Needle-Free
updated: 28 July 2000
2 of 2
7/28/00 3:52 PM

<<<PAGE 13>>>

Biojector 2000 Description & Specifications
http://www.bioject.com/Information/Product_Description/
...
Biojector 2000 Description & Specifications
The System
The Biojector is a high speed delivery system designed to inject medication intramuscularly (IM) or
power source to eject mediation through a tiny orifice in a fraction of a second, effectively penetrating the
subcutaneously (SC) without a needle. The Biojector employs compressed carbon dioxide (CO2) as
skin.
Energy Source
The Biojector is energized by a standard CO2 cartridge. Each CO2 cartridge delivers an average of 10
injections with proper technique. Installing the CO2 cartridge is a simple procedure, which is described in
the Instruction Manual. The CO2 does not interact with the medication.
Sterile, Single-Use Biojector Syringe
The Biojector is the first jet injector in history to delivery medications from a sterile single-use syringe.
unique feature virtually eliminates the risk of bloodborne pathogen cross-contamination to patients and
i his plastic syringe is the only part of the system that comes in contact with the patient's skin. This
healthcare providers.
Advances on Proven Technology
Pneumatically powered injectors have been used for many years. Millions of injections have been given,
proving that this technology is efficacious. Jet injectors were most widely used to immunize large
numbers or people quickly and economically. All of these early devices injected through a stationary
was learned that the stationary nozzle, through which the medication was ejected, could pass bloodborne
nozzle, which required labor intensive rinsing, cleaning and sterilization for proper maintenance. Later, it
pathogens from one patient to another. This cross-contamination problem has been eliminated by the
B2000.
Unique Design
Several important design elements distinguish the Biojector from other jet injection devices.
The Biojector removes the possibility of cross-contaminating patients through use of a disposable
single-use syringe. After each injection, the old syringe is discarded and a new one is inserted for the
next patient. Because of this design, sterilization and daily maintenance are not necessary.
Needle-Free Injections
into the syringe. The needle is then discarded and the filled syringe is inserted into the device. A sterile,
The Biojector Syringe is packaged with a fill needle, which is only used to draw medication from a vial
protective cap is provided to prevent touch contamination. This cap is placed over the filled syringe
is placed firmly against the skin at a 90° angle, and the actuator is pressed and released to delivery the
before the injection. After inserting the syringe into the injector, the protective cap is removed, the injector
injection. Five different syringe sizes allow the clinician to achieve various penetration depths for an
intramuscular or subcutaneous injection, depending on the patient's body size. The needle-free syringe
eliminates "needlephobia" and reduces patient anxiety associated with injections. Many people seem to
truly fear injections and may avoid seeking health care because of this phobia.
Patient Preferred
1 of 2
7/28/00 3:56 PM

<<<PAGE 14>>>

Biojector 2000 Description & Specifications
http://www.bioject.com/Information/Product_Description/
degrees or pain have been experienced with injections administered by both needle/syringe and jet
Delivery of medication through the skin creates some physical sensation in nearly every case. Varying
injection. Work with jet injectors shows that patient acceptance seems to be higher since the injection is
reasons: It decreases the fear of a traditional needle injection. It appears less intimidating than the
delivered more rapidly. (1,, Patients have preferred the Biojector over needle/syringe for the following
traditional needle/syringe'. The injection occurs in a fraction of a second )
Local Site Reaction
Depending upon the characteristics of the injectate, most people report little to no pain with a Biojector
injection. Some drug preparations contain components that cause stinging, burning, aching or other
painful reactions and this does not change with the Biojector. Bioject recommends that the medicatio
package insert be read carefully so each patient can be advised of a medication's side effects.
Product Specifications
* Size: 8.5 inches (22 cm)
* Weight: 20.5 ounces (580 grams)
* Operation Temperature Range: < 60°-100°F (14°-38° C)
* Power Source: CO2 Cartridge
* Injections per CO2 Cartridge: 6 - 10
* Pressure Indicator: Yes
* Syringe/Actuator Interlock: Yes
* Recommended Service and Calibration Interval (for the Biojector): 18 months
* Warranty: One Year
* Administration: Intramuscular and subcutaneous under the direction of a physician
To request product literature or to order products or training materials:
BIOJECT
Bioject Inc.
Write:
Call: 800/683-7221 Ext. 436
Home Page
Customer Service
7620 SW Bridgeport Road
E-Mail:
Portland, OR 97224
customerservice@bioject.com
Injection Management Systems are trademarks of Bioject Inc. Last
Biojector® is a registered trademark, and Bioject and Needle-Free
2 of 2
7/28/00 3:56 PM

<<<PAGE 15>>>

http://www.bioject.com/faqs/
Frequently Asked Questions about the Biojector
How does the Biojector work?
The Biojector uses compressed gas (carbon dioxide) and sterile, disposable medication syringes to
the power to deliver your medication. It never comes in contact with the medication or your skin. The
deliver medication into the body's tissue without using a needle. The compressed gas simply provides
actual injection is over in a fraction of a second.
What does a Biojector injection feel like?
explain if you should expect any of these reactions from the medication you are receiving.
when injected. These are normal sensations and should go away in a short time. The doctor or nurse can
What kinds of injections can be administered with the Biojector 2000?
Intramuscular (IM) and subcutaneous (SC) injections can be administered with the Biojector 2000.
How does the device administer the different depths of penetration?
the number of syringe, the deeper the penetration of the injection.
The size of the orifice, or hole, though which the medication is ejected varies by syringe size. The higher
Can I buy a Biojector 2000 for home use?
is important to be trained by a medical professional on how to administer injections with the B2000.
Yes, but you must have a prescription from your physician. Using the Biojector is fairly simple, however it
Is the Biojector 2000 covered by my insurance?
You will need to contact your insurance company for information about medical device coverage. Some
cover the entire cost, while others do not.
What other products are available from Bioject?
Besides the professional device, the B2000, Bioject also offers the disposable syringes and the
compressed gas (CO2) cartridges.
Is Bioject ISO 9000 Certified?
•
9001 and EN 46001.
Yes, Bioject received its ISO 9000 certification on January 28, 1999. Bioject is currently certified to ISO
What is ISO 9000 and what does it mean to Bioject?
1 of2
7/28/00 4:09 PM

<<<PAGE 16>>>

Frequently Asked Questions about the Biojector
http://www.bioject.com/faqs/
ISO certification is based on meeting a series of internationally accepted quality system standards
ISO, from the Greek term "isos" meaning "equal," has been extrapolated by the standards organization
developed by the International Organization for Standardization adopted in 1987 and revised in 1994.
requirement and will help facilitate regulatory clearance requirements in Europe and other countries,
mean an equal standard for quality system management. ISO 9000 has become an international
ISO 9000 certification as a benchmark for quality systems. It also provides a structure to increase both
thereby increasing sales. It is also a requirement of many US businesses that have come to recognize
product and process quality and will help improve competitiveness, both in the United States and abroad.
Is the Biojector approved by the FDA?
lat the Biolector can be sold in the US
nder FDAS regulations, the Bectr20 has been cleared for marketing in the USA. Which mear
How much does the Biojector, syringes, and CO2 cartridges cost?
customerservice@bioject.com
anager to contact vou regarding pricin
For additional information:
BIOJECT
Bioject Inc.
Write:
Call: 800/683-7221 Ext. 416
Home Page
7620 SW Bridgeport Road
Customer Service
customerservice@bioject.com
E-Mail:
Portland, OR 97224
Biojector® is a registered trademark, and Bioject and Needle-Free
Injection Management Systems are trademarks of Bioject Inc. Last
updated: 5/4/99
2 of 2
7/28/00 4:09 PM

<<<PAGE 17>>>

8/2/00
Hattee -
manufacturer du the
Carboa dioxide Alidar
useato administe,
medications.
and deterneie of this
Coupe under 0(4)))
Thawks-fee yeu Twes
Gigi

<<<PAGE 18>>>

.*
.. -
BJOJECT
HOJECT INC
FACSIMILE TRANSMISSION COVER SHEET
PCATUNO, CREGON 9724
FAX: (303) 0249002
TELEPHONE: (S03) aJ9-T22I
Transmitting Fax Number: (503) 624-9002
• .
Troubleshooting Number: (503) 639-7221
Date:
121/00
Receiving Far No: 326 - 2127
The following document consists of _12 page(s) including this cover sheet 2)
Please call the troubleshooting number above if pages are not received.
PLEASE DELIVER FHIS TRANSMISSION TO
Name: Don S7:9483
Company: FAA
Department: 1X32-mgs
FEIS DOCUMENT IS EROM:
Name:
i chas Sport me
Comments:®
DOn,
HEss is the tato Ws DiscussEDi
Ass tha spres for your " Lits Incers?
Rs4oo
Richon
THE ORIGINAL DOCUMENT BEING TRANSVIFIED:
will not be sent to you
- Will be sent by overnight mail
will be sent by regular mail
_ other:.
CONFIDENTIALITY NOTICE: This facsimile [this page and any accompanying pages(s)] is intended only for the
use of the individual or entity to which it is addressed and may contain information that is privileged, confidential
and exempt from disclosure under applicable law. If the reader of this message is not the intended recipient or the
employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that the
unauthorized dissemination, distribution, or copying of this communication, or the taking of any action in reliance
on the contents of this information, is strictly prohibited. If you have received this facsimile in error, please notify
Service. Thank you.
us immediately by telephone (collect), and return the original message to us at the above address via the U.S. Postal

<<<PAGE 19>>>

A NEW ERA OF PARENTERAL
THERAPY IS AT HAND
He technongy
Proven clicacy
7 Unique portable
design
• Easv to learn
easy to use
Contaminated needlestick injuries extract an enormous toll on today's
¡Safer cost-effedive
healthcare industry threatening the well being of medical
disposal
professionals and costing healthcare providers
millions of dollars annually.
delivery method for subcutaneous and
Now there is an effective needle-free drug
LEGERTANC
#Maintenance-free
intramuscular injections that prevents
contaminated needlestick injuries and the
subsequent spread of bloodborne pathogens.
Because it is easy to use and patient preferred, it
Value added
marks a new standard of care for administering
cost-in-use
injections.
The Biojector 2000 Needle-Free Injection Management System
delivers medications parenterally without a needle. Instead, the
• Eliminates fear
Biojector uses compressed carbon dioxide (COz) as a safe
associated with needle
power source to eject medication through a micro-
injections
323"
orifice within a fraction of a second. This delivery
action effectively penetrates the skin and delivers
the medication into the patient's tissue.
The Biojector eliminates costly maintenance
and the threat of cross-contamination with its
unique, patented, disposable medication syringe.
Once an injection is given, the needle-free syringe
GÖLD 1293
BIOJECT
is discarded. Single-use Bioject syringes provide safe
injections for patients and needle-free drug delivery for
medical professionals, advancing the overall quality of
Safety. Innovation. Quality.
healthcare.
The future of needle-free drug delivery is here.

<<<PAGE 20>>>

PRODUCT INFORMATION
Syringe No.
Order No.
Biojector 2000 Needle-Free Injector ..
#1B02000
Biojector Syringes
(Box of 100, up to 1.0 cc variable-dose)
No. 2 Needle-Free Syringe
#1S02100
No. 3 Needle-Free Syringe
#1503100
No. 4 Needle-Free Syringe
#1S04100
No. 5 Needle-Free Syringe
#1S05100
No. 7 Needle-Free Syringe
#1S07100
CO, Power Cartridges (Box of 10)
#1CO8010
*#*****
CUSTOMER SERVICE AND ORDERING INFORMATION
Bioject is committed to providing the best possible service and
• Orator Temperature
Range
support. Our customer service representatives are well qualified
6000380
and readily available to answer any of your questions regarding
the Biojector 2000.
o Weighte
:230z. 640 grams!
Contact Bioject Customer Service at:
(800) 683-7221 ext. 436, or
(503) 639-7221 ext. 436
cin, (22 cm) lo
Or write:
ressure Indicator:
Bioject Inc.
Customer Service
7620 SW Bridgeport Road
Syringe Secured Indicator
Portland, OR 97224
Inservice video tapes and educational materials are also available
yringe Actuator Interlock
upon request from Bioject's Customer Service Department.
Recommended Service and
Calibration In
terv
18 months
BioTector
Warran
One
GOLD 1293
All sales are subject to Bioject's standard terms and conditions.
Prices are subject to change without notice.
1. Leads from the MIMWR. Hepatitis B associated with jet gun injection-California.
JAMA. 256(4): 446-447; July 1986.
Biojector is a registered trademark, and Bioject and Needle-Free Injection
subsidiary, Bioject Inc.
Management System(s) are trademarks of Bioject Medical Technologies Inc. and its
BIOJECT
@Copyright 1994 Bioject Inc. All rights reserved. 171-0117-04, Rev. B, 3/96
Safety. Innovation. Quality.

<<<PAGE 21>>>

BIOJECTOR® 2000
Product information and benefits of the
Biojector 2000 Needle-Free
Injection Management System
BIOJECT®
Needle-Free Injection
Management Systems

<<<PAGE 22>>>

CONTENTS
DESCRIPTION
The System.
..2
Energy Source
...2
Sterile, Single-Use Biojector Syringe.
...2
Advances on Proven Technology
..3
Unique Design
....
Needle-Free Injections
..3
Patient Preferred
•4
Local Reactions.
.4
Customer Service
.4
Product Specifications.
.4
BENEFITS OF THE BIOJECTOR
Healthcare Worker Benefits
No Contaminated Needle:
Safer for the Healthcare Worker
Proven Efficacy.
Easier Disposal
Maintenance Free
Cost Effective
5
Patient Benefits
..6
No Needle: Safer for the Patient.
6
No Needle: Patient Preferred
.6
Faster and Easier Delivery
..6
Less Tissue Trauma
.6
Biojector® is a registered trademark, and Bioject®
and Needle-Free Injection Management
REFERENCES
6
Systems are trademarks of Bioject Inc.

<<<PAGE 23>>>

DESCRIPTION
2
The System
The Biojector is a high speed delivery system designed to inject medication
intramuscularly (IM) or subcuraneously (SQ) without a needle. The Biojector
mploys compressed carbon dioxide (CO,) as a power source to eject
nedication through a tiny orifice in a fraction of a second, effectivel
penetrating the skin.
Biojector®
Energy Source
The Biojector is energized by a standard COr cartridge. Each COz
cartridge delivers from 6-10 injections with proper technique. Installing the
COr cartridge is a simple procedure, which is described in the Instruction Manual.
The COz never interacts with the medication.
Sterile, Single-Use Biojector Syringe
single-use syringe. This plastic syringe is the only part of the system that comes in
The Biojector is the first jet injector in history to deliver medications from a sterile
contact with the patient's skin. This unique feature virtually eliminates the risk of
bloodbore pathogen cross-contamination to patients and healthcare providers.
-d-s

<<<PAGE 24>>>

DESCRIPTION
Advances on Proven Technology
athogens from one patient to another. This cross-contamination problem has bee
ne stationary nozzle, through which the medication was ejected, could pass bloodborn
eliminated by the B2000.
Unique Design
Several important design elements distinguish the Biojector from other jet injection
devices.
and daily maintenance are not necessary:
Needle-Free Injections
The Biojector Syringe is packaged with a fill needle or vial adapter which is only used
before is emoted, lifer inter is placed ingle no che the cos at a roacie,
and the actuator (switch) is pressed and released to deliver the injection.
Five different syringe sizes allow the clinician to achieve various
penetration depths for an intramuscular or subcutaneous injection,
depending on desired depth of penetration.
The needle-free syringe eliminates "needlephobia" and
reduces patient anxiety associated with injections.
Many people seem to truly fear injections and
may avoid seeking health care because of
this phobia.

<<<PAGE 25>>>

DESCRIPTION
Patient Preferred
every case. Varying degrees of pain have been experienced with injections administered
Delivery of medication through the skin creates some physical sensation in nearly
ceptance seems to be higher since the injection is delivered more rapidly'
, both needle/syringe and jet injection. Work with jet injectors shows that patier
Patients have preferred the Biojector over needle/syringe for the following reasons:
• It decreases che fear of a traditional needle injection
• The injection occurs in a fraction of a second
• It appears less intimidating than the traditional needle/syringe injectior
Local Reactions
Customer Service
Loger Customer ervice, - 683-72 01 305-69.121, akable upon request from
Product Specifications
Size:
Weight
..8-1/2 inches (22cm)
Power Souree:.......
Operation Temperature Range
..20.5 ounces (580 grams)
..60°-100°F (14°-38°C)
Injections per CO, Cartridge:
GO, Cartridge
Pressure Indicator:
Syringe/ Actuator Interlock:
Yes
Recommended Service
.Yes
and Calibration Interval
Warranty:..
(for the Biojector):.
.18 months
Administration:...
Intramuscular and subcutaneous
.12 months
a physician
injections under the direction of

<<<PAGE 26>>>

...
5
BENEFITS OF THE BIOJECTOR
Healthcare
No Contaminated Needle: Safer for the Healthcare Worker
Worker
Benefits
Proven Efficacy
Selection Guide.
Easier Disposal
Maintenance Free
he Biojector System is the only pneumatic device which employs a sterile
terization or eating alet each usectors, the Biojector does not requir
Cost Effective
The cost to investigate and treat needlestick injuries has soared. A portion of
these costs includes those with employee time loss, replacement, or medical
treatment should the healthcare worker develop a positive test for hepatitis
The Biojector eliminates the contaminated needle and removes the risk of
associated with this benefit are measurable not only in direct costs, but also
bloodborne pathogen transmission through accidental needlesticks. The savings
in improved employee morale and productivity.

<<<PAGE 27>>>

BENEFITS OF THE BIOJECTOR
6
Patient
No Needle: Safer for the Patient
The liquid stream of medication takes the path of least resistance and flows
Benefits
around nerves and blood vessels rather than chrough them. The Biojector
No Needle: Patient Preferred
Faster and Easier Delivery
The Biojector delivers a variable dose up to 1.0 cc in a fraction of a second.
Less Tissue Trauma
Published clinical studies report that there is less scarring, tissue trauma and atrophy
hen medication (such as insulin) is delivered via jet injection as opposed to
aditional needle/syringe
REFERENCES
1.
Nov. 1982.
McKenzie R. Clinical applications of jet injection. NZM]. 720:815-817;
2.
Hes So as tal, Tunition and mass therapy ease upon two decades
xperience. Military Med. 516-524; June 1963
3.
Neufeld P, Katz L. Comparative evaluation of three jet injectors for mass
immunization. Can J Pub Hlth. 68:513-516; 1977.
4.
method. JAMA. 195:156-159; 1966.
Weller C, Linder M. Jet injection of insulin vs. the syringe and needle
*12"

<<<PAGE 28>>>

BJOJECT®
Needle-Free Injection Management Systems
7620 SW Bridgeport Road
Portland, Oregon 97224
503/639-7221
800/683-7221
www.bioject.com
Copyright© 1998 Bioject Inc.
171-0119-01 Rev. B (9/98)
All Rights Reserved

<<<PAGE 29>>>

07/21/00
FRI 11:45 FAA 503 620 6431
BIUJECT
40001
" "i
*********************
***
*********************
IX REPORT
***
TRANSMISSION OK
IX/RX NO
CONNECTION ID
CONNECTION TEL
4105
18567517289p40
USAGE T
ST. TIME
07/21 11:29
16'06
PGS. SENT
RESULT
OK
24
BJOJECT
July 21, 2000
FAX: (503) 624-7002
TELEPHONE: (G03) 639-7221
WWW.BOJECT.CCM
RE:
Bioject Product Information
Thanks for your inquiry regarding the Bioject Needle-Free Injection System. The Biojector® 2000 uses
use of a needle. It is a safe, effective delivery method for subcutaneous and intramuscular injections.
compressed carbon dioxide (COz) to deliver medication through a disposable, single-use syringe without the
The features which differentiate our Biojector® 2000 system from other needle-free injection devices are:
:
Administers up to 1 ml. of injectate
Delivers either subcutaneous or intramuscular injections, as indicated by the
•
Eliminates completely the risk of cross contamination between patients, and the risk of accidental
medication/ vaccine labeling
Administers different types of medication with the same device, using single use,
needle- stick injuries for healthcare professionals
• •
Reduces the volume and expense of hazardous medical waste (sharps) disposal
Ease of training and use for medical technicians and health care professionals
High level of patient acceptance
Extremely portable
Addresses the sharps-safe issues raised by recent OSHA legislation.
• Each Biojector 2000 Injector
$675.00
• Each box of single use, sterlle, disposable needle-free syringes
(100 SC or IM syringes per box)
$67.00
• Each box of CO, power cartridges
$5.00
(10 CO, cartridges per box)
National Sales Manager, Mr. Kurt Lynam, at 503/639-7221 extension 501. If you would like to contact one of
For additional information regarding ordering and pricing, please contact elther myself (Ext. 436), or our
our nurses for additional clinical information please contact Tricia Diamond at extension 578.
you need any additional information.
Thanks again for your Interest in Bioject's products and technology. Please contact us at the number below if

<<<PAGE 30>>>

10/18/00 WED 11:49 FAX 503 624 9002
BIOJECI INC.
Ø1001
BIOJECT INC.
FAX
Date:
10-18-200
Number of pages including cover shes:
19
To:
From: "
6161 CORDiN
Tem BRooks
-
•
Phone:
Phone:
(505) 639-7221
Fax phone: 202-366-3012
Fax phone:
(503) 624-9002
CC:
-
REMARKS:
Urgent
• For your revier
• Reply ASAP
Please commem
•
BIOJECT
7620 S.W. BRIDGEPORT ROAD
PORTLAND, OREGON 97224

<<<PAGE 31>>>

10/18/00 WED 11:49 FAX 503 624 9002
BIQJECE INC.
0002
INDUSTRIAL PRODUCTS
PRODUCT INFORMATION
Product Rango
STANDARDS ........
....... EN, DIN, TÚV, DOT. MOD. BS, MIL. FAA. TSO, ASTM, EMPA, DAN
Conversion Factors
FILLING
Mutliply
By
To obtoin
Carbon Dioxide (COz). Nitrogan (Na)
SURFACE TREATMENT........ Electroplated Zinc. Super (high corrosion resistant) Zinc
mm
0.0394
In
am?
MARKING........
0.155
..... InkJet. Engraving or Printing to specification
cm° (1 ml)
0,061
in
Seleot from table below, Other sizes, gases and fillings on request.
Nominal Weight(s)
of COa
Copacity
Water
Diameter
Body
Length
Overall
Newton
0.225 •
ibf
rams
mi
mm
mm
Neck detalts
0.454
kg
kg/am?
bar
14.22
Ibf/in?
10
18
66.5
10.5 & 12
3/8° × 24 UNF 1A
14,5
Ibf/in?
10 & 11.5
19.6
82.5
8.7 mm Dia PLAIN
atmosphere
1.013
N/mm?
145
bar
18.6
82.5
12
18.6
3/8° × 24 UNF 1A
16
82.5
7.3 mm Dia PLAIN
US gallon
3.785
litres
22
88.5
8.7mm Dia PLAIN
UK gallon
4.546
Hitres
16
16
22
8B.5
22
B8.5
8,9 mm Dia PLAIN
US fluid ounce
29.57
• ml
20.23 & 24
3/8" × 24 UNF 1AV2A
28
254
105
20.7
1/2" × 20 UNF-TA:
28
160
8.7 mm Dia PLAIN
28, 30 & 33
20.7
160
3/8° × 24 UNF 1A
25.4
139
35 & 38
1/2° × 20 UNF 1A
FOR VARIOUS FILLING DENSMES OF CO
PRESSURE - TEMPERATURE
30
118
1/2° × 20 UNF 1A
45
30
55 & 60
138
1/2° x 20 UNF 1A
Hing densily Water copacity (mil)
Wt of CO2 (g)
75
31.8
163
1/2° × 20 UNF 1A
31.8
B4
189
1/2° × 20 UNFIA
600
/ 0.00/0.251
41.3
86
145
35
1/2°x 20 UNF IA
Made
120' & 135°
198
1/2" × 20 UNFIA
400
10.60
50
176
120, 135 & 150
1/2" × 20 UNF 1A
50
171
215
1/2° × 20 UNF 1A
226
1/2° × 20 UNF IA
50
275
1/2° × 20 UNF 1A
300
DABE
230*
290°
60
296
225
1/2" × 20 UNF IA
60
213
1/2° × 20 UNG \A
200
315
50
330°
311
1/2° × 20 UNF 1A
60
50
375
1/2° × 20 UNFIA
345
60
265
1/2° x 20 UNF 1A
100
450
311
460°
1/2° × 20 UNF 1A
60
368
1/2°x20 UNF IA
Product range may be updated. Please cheok with us.
TEMPERATURE (C) →
120
160
Physical Characteristics
Carbon Dioxide (COz)
Odour
Nitrogen (N2)
Slightly pungent
Taste
None
Acidic/Biting
None
Fire hazard
Non-flammable
Non-flammable
Toxicity
Iquid densily (20°C)
Max. 0.5% v/v continuous
Non-toxic
0.775 kg/l
Gas density (15°C and 100 KPa)
-
1.85 kg/m (g/D
1.17 kg/m (g/l

<<<PAGE 32>>>

10/18/00 WED 11:50 FAX 503 624 9002
BIOJECI INC.
• har.
AUG 17 '98 17:14 FR ISI NORTH AMERICA
973 227 9140 TO 15036249802
@003
AMS AEMUUAMAIAN
→97 L5: UJA
P.02
: 8 GRAM CO, (E)
8.7mm PLAIN NECK
ARTICLE No: YH1 J
• B8.7=5.05
27.3000
82.5'
PIERCING ASEA LITHIN
0.3 ASOVE DA BELO
HIS SURFID
NẸT WEIGHT
PULLGEW!CHT
COZ
POIDS DE REMPLISSAGE EN CO
8:0.3G-
VOLUMEN
WATER CAPACITY
10.2 al
CAPACITE EN EAU
MIN
MIN 6.5,
FILLING DENSITY
FULLFAKTOR
81% -
• FACTEUR DE REMPL ISSAGE
MAX
PRÜFDRUCK
TEST PRESSURE
250
PRESSION D'ESSAI
BAR
BURST PRESSURE OF CYLINDER
64.510.3
BERSTDRUCK DES ZYL INDERS
>500
PRESSION D'ECLATEMENTE DU CYL INDER
BAR
KAPPEN ANSTECHKRAFT
CAP PIERCING FORCE
FORCE DE PERCUTION
$300 N
CO, (E290) - iSi SPEC 0192 - 99.95% PURITY
MARK ING PROCESS: INK JET
MARK ING:
INSCRIPTION:
INSCR S(X AUSTRIA MY
MIN.GR.WT XX.XG
PRINTING REPEATED THREE TIMES
AROUND THE CYL INDER
PACKING: LOOSE, IN CARTONS OF 430 PCS
CARTON MARKING: CARBON DIOXIDE: 2.2; UN1013
WT OF CARTON: 12.5 KG
018:002
G
COPYRIGHT
2
ISi
198-07-26
i5: dabt
TITLE: 8G CO, PLAIN NECK GYLINDER
1
RS
A-Izta Tim.
(85-05-25)
Küractmergosso 1
8G OO, ZYL INDER CHNE HALSGEWINDE
title
RS
rece producta are tha nuojam, uí petent.
Iss.No.
Bate
chonge
Name
alion in AUSTRIÀ, fURORE unt principel
BOUTEJLLE DE &G CO. SAMS FILETAGE
Data
au ai thu morió. Thin drawing and mll
Nome
în epa
dolion or duncriplive natler cet out
Mot:
SPECIAL DEEP DRAW ING STEEL.
W-NR.7.0338 DIN 1624
droom
98-04-08
RS
n3l ast
& dlunlerad Inanad canioe op uud
confidengiel ond copyright nd
OrgNo: YH1 J 2
Surface
Scaia
for parurocluring lendering dr olnue purposes
- **truncated:** true
- **body characters:** 69611