# Hospitec — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 00-0296
- **title:** Hospitec — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2000-11-09
- **effective on:** Not available
- **summary:** 00-0296 response to Hospitec concerning 173.197.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0296.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0296.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0296
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2000/000296.pdf
**body:**

<<<PAGE 1>>>

U.S.Department
of Transportation
Washington, D C
400 Seventh Street, S.W.
20590
Research and
Special Programs
Administration
NOV - 9 2000
Mr. Christopher Hahn
Reference No. 00-0296
Vice-President, Sales
Hospitec
285 Granada Road
West Palm Beach, FL 33401
Dear Mr. Hahn:
This is in response to your letters and conversations with members of my staff concerning the
requirements for a regulated medical waste packaging under § 173.197 of the Hazardous
Materials Regulations (49 CFR 171-180). Specifically, you asked if a plastic sharps container
that is puncture-resistant, leakproof, and has passed requirements in 49 CFR Part 178 at the
Packing Group II performance level is required to have a polyethylene liner (red bag). You
state that the liner was shredded during each test.
If the use of a plastic liner is not necessary to that packaging's performance, such as to satisfy
the moisture or leak resistance criteria, there is no requirement under § 173.197 to use a liner.
I hope this satisfies your request.
Sincerely,
Hathe R. Mittell
Hattie L. Mitchell
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials Standards

<<<PAGE 2>>>

Oct 13 D0 12:28p
Christopher Hahn-Hospitec 561-833-9179
P.1
1à :
t3m134
Reaulated Medical
Hospitec ne.
.. Beyond tills.
Waste
FAX
203 - 502 Bow Valley Trail
Canmore Alberta
Company: D.0.J-
Canada TIW IN9
Tcl: 403-609-4330
5ax: 707-366-3012
Fax: 403-609-4337
Toll Free: 1-800-337-2885
Pages (Including Cover): 2
Email: office@hospitecinc.com
COVER
Date: 10/13/00
From: CHRIs HAnD
Reference:
QUESTION REGARDINO REGULATES
IN ERROR OR THE INFORMATION IS UNCLEAR, PLEASE NOTIFY US IMMEDIATELY BY TELEPHONE.
THIS FAX CONTAINS INFORMATION THAT IS PRIVILEGED AND CONFIDENTIAL IF YOU HAVE RECEIVED THS COMMUNICATION
TAIL IS MY SULONA TINE RESUMMITINE TATE
ATTACHES QUESTION. I GRIGINAL SUMMITTRO
TAIS QUESTION TO FILEEN FEDMONSON ON
JuLy 26, J000 AND sAua NoS RECEIVEs
A RESPONSE BACK. WOULD yOU BE KINO
FENDOGA TO GIUE ME A RESPONSE AS yOUR
EARLIRST CONVENIENCE, IT IS IMPONTANT THAT
I HAVa TAHS INFONMATTON AS SOON AS POSSIBLEE,
SO I CAN PROVIDE SOMETHING IN UNITINE TO
My CUSTUMERS TARE ARE REQUESDINA IT. DOT.
BUT I NICO SOMETHINE AN
§ NOT NECESSANY,
UNITING TO SAMSFY MY CUSTUMERS , TANK 400.
BEST REGAROS,
PAMIC

<<<PAGE 3>>>

Oct 13 00 12:28p
Christopher Hahn-Hospitec
561-833-9179
p.2
Eamnonson
8 173.134
Hospitec Regulated Medical Waste
October 13, 2000
Mr. Edward Mazzullo
Director of Hazardous Materials Standard
U.S. Department of Transportation
Research and Special Programs Administration
400 Seventh St., S.W.
DHM-10
Washington, DC 20590-0001
Dear Mr. Mazzullo:
I would appreciate some clarification in writing regarding the testing protocol used for the testing
(red bag) be placed inside a puncture-resistant, leak-proof plastic sharps container that has passed
of Group Il Packaging of Regulated Medical Waste. Is it required that a polyethylene plastic liner
the Packaging Group II Performance Standards?
I would like to add, that when the festing of our containers was completed by Ten-E Packaging
Services, it was reported to us that the plastic liners served no purposo, since the inside liner
also informed by two D.O.T. Enforcement Specialists that the inner liner was not written into the
would always fail, due to the fact, that it always shredded from the sharps material inside. I was
protocol, and was not necessary. Unfortunately, I found this out after the testing was completed.
Please send response to the following address: 285 Granada Road, W. Palm Beach, FL 33401.
Thank you for your help.
Sincerely,
aDar
Christopher Hahn
Vice-President of Sales
Innovations in Healthcare
- **truncated:** false