# C&R Fleet Services, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 00-0338
- **title:** C&R Fleet Services, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2001-04-30
- **effective on:** Not available
- **summary:** 00-0338 response to C&R Fleet Services, Inc. concerning 180.416.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0338.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0338.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-00-0338
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2000/000338.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Washington, D.C. 20590
400 Seventh St., S.W.
Research and
Special Programs
Administration
APR 3 0 2001
Ms. Michelle Cannon
C&R Fleet Services, Inc.
Ref. No. 00-0338
353 O'Dell Road
Griffin, Georgia 30224
Dear Ms. Cannon:
This responds to your request for interpretation, dated December 4, 2000, concerning rejection
criteria specified in the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) for
hoses on cargo tanks used for the transportation of liquefied compressed gases. Specifically, you
ask if a hose that has sustained minor damage to the outer hose covering must be removed from
service. You provided samples of two hoses to illustrate your question.
Section 180.416(g)(1) of the HMR establishes rejection criteria for hoses on cargo tanks used to
transport liquefied compressed gases. Paragraph (g)(1)(i) requires a hose with damage to the
hose cover that exposes the reinforcement to be removed from service. In the sample of the
damaged hose you provided, hose reinforcement is accomplished by means of a nylon-type
material interwoven in the hose assembly and extending to the outer edge of the rubber outer
hose covering. The damage to the sample hose exposed the nylon reinforcement. In this case,
the hose would need to be repaired and tested prior to use.
The second sample hose you provided has several layers of protection between the rubber outer
hose covering and the nylon reinforcement. This type of hose may continue to be used with
minor damage to the outer hose covering, provided the nylon reinforcement layer is not exposed.
A hose that has sustained damage sufficient to penetrate the outer layers and expose the nylon
reinforcement must be repaired and tested prior to use.
I hope this information is helpful. If you have further questions, please do not hesitate to contact
this office.
Sincerely,
Thi
is. Call
•cim
Thomas G. Allan
Senior Transportation Regulations Specialist
Office of Hazardous Materials Standards

<<<PAGE 2>>>

Gorsky
3180.41629()
Cargo Tank
00-0338
December 4, 2000
Hazardous Materials Division
Research and Special Programs Administration
Department of Transportation
Washington, DC 20590-001
C & R Fleet Services, Inc
353 O'Dell Road
Griffin, Georgia 30224
Subject: Request for Interpretation of Hazardous Material Regulation 180.412(g)(i)
Sir:
This letter is to request an interpretation of the rejection criteria for hoses involved in the
transportation of liquefied compressed gases. Specifically, paragraph (g) (i) of section
180.412, "Damage to the hose cover that exposes the reinforcement."
Hoses used in the transfer of liquefied compressed gasses are made up of many layers of
reinforced material. In the past, because of lack of specific pass fail criteria, the industry
has assumed that minor damage to the outer covering that exposes only one or two of the
reinforcement layers was not a failing condition because, the structural integrity of the
hose is not compromised. In fact, in many instances, the hose will pass a pressure test to
120% MAWP with several layers of reinforcement exposed.
These hoses are exposed to a great deal of rubbing as the result of vibration during the
transfer of product and frequently the first layer of reinforcement, only millimeters from
the surface of the hose, may be exposed after only one or two uses. In this case, the
structural integrity of the hose is not compromised but the literal interpretation of Sec
180.416 (g)(i) is that the hose is out of service and must be replaced.
Please advise us as to how much of the hose reinforcement may be exposed before the
hose must be removed from service.
If you require additional information please feel free to call (770) 412-8211.
Thank You,

<<<PAGE 3>>>

B..i
•
2.., 7
Gorsky, Susan
From:
Sent:
Shelton, Daniel <FHWAS P
wei.Btetton@fhwa.dot.gov]
Subject:
To:
Gorsky, Susan <RSPA>
Tuesday, December 05, 2000 1:46 AM
Fwd: Request for Interprolation
ENCLOSURE
Request for Ruking.doc
our discussions
Susan, attached de 4 request for interpretation resulting from
Last week at a cargo tank seminar in charlotly, forth Carolina.
Based on the feedback from the participants, sidely rubbing the hose through
the first layer of rubber reinforcement does hot compromise the integrity of
reinforcement and then up to twelve layers of rubber reinforement on the
These hoses are constructed of an inner linner, then a wire
outside.
If you need additional information contact le or Michelle at the company.
She left her phone number and address.
Thanks again.
Carish
:

<<<PAGE 4>>>

. Anthony Reid
RI - CT 7588
- **truncated:** false