# SENSIDYNE — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 02-0092
- **title:** SENSIDYNE — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2003-02-13
- **effective on:** Not available
- **summary:** 02-0092 response to SENSIDYNE concerning 173.4.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0092.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0092.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0092
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2002/020092.pdf
**body:**

<<<PAGE 1>>>

of Transportatior
J.S. Departmeni
400 Seventh St., S.W.
Research and
Washington, D.C. 20590
Special Programs
dministration
FEB | 3 2003
Mr. Ron Roberson
Ref. No.: 02-0092
Corporate Industrial Hygienist & Technical Manage
SENSIDYNE
16333 Bay Vista Drive
Clearwater, FL 3376088
Dear Mr. Roberson:
This responds to your letter regarding the small quantity exceptions under the Hazardous Materials
Regulations (HMR: 49 CFR Parts 171-180), as they apply "smoke tubes" sold by your company. We
apologize for the delay in responding and hope it has not caused any inconvenience.
According to your letter, the smoke tubes are used to track air currents in ventilation studies and to test
respirators for proper fit in accordance with OSHA standards for irritant fume respirator fit test
protocol. Each smoke tube consists of a pencil-sized sealed glass tube filled with pumice granules
coated with approximately one gram per tube of "Stannic chloride, anhydrous, 8, UN 1827, II." The
tubes are activated by breaking off the ends and pushing ambient air through with a small rubber bulb or
motorized pump. Moisture in the air reacts with the stannic chloride and produces the smoke. The
smoke tubes are sold in a box of ten tubes.
A material described as "Stannic chloride, anhydrous, 8, UN 1827, IN" may be transported under the
small quantity exception if it meets the quantity limits and packaging requirements in § 173.4, and is not
forbidden under § 173.21. Based on the description of the "smoke tubes".
may be transported under the small quantity exception provided the quantity of the Class 8 (corrosive)
, it is our opinion that they
material in the inner packaging (i.e., glass tube) is less than 30 grams (1 ounce) and all other provisions
of § 173.4 are met. A package shipped in accordance with the small quantity exceptions in § 173.4 is
not subject to any other requirements of the HMR, including labeling. The "smoke tubes" may also be
shipped under the limited quantity exceptions for corrosive materials in § 173.154, which excepts such
packages from the labeling requirements, unless offered or intended for transportation by aircraft.
I hope this satisfies your inquiry. If we can be of further assistance, please contact us.
Sincerely,
Delmer F. Billings
Chief, Standards Development
Office of Hazardous Materials Standards
113.4
020092

<<<PAGE 2>>>

Engrum
5173.4
SENSIDYNE: Small Quantity
xceptions
16333 BAY VISTA DRIVE, CLEARWATER, FLORIDA 33760 USA 02-0092
TEL: 800-451-9444, (727) 530-3602 (FL)
FAX: (727) 539-0550
COMPANY: US DOT Ofeof Haz Mat Safety FROM:
Ron Roberson
FAX:
202-366-3012
DATE:
March 25, 2002
ATIN:
Delmer Billings.
PAGES:
1
OF.
- 1
SUBJECT:
Ventilation Smoke Tube Shipping
MESSAGE
Dear Mr. Billings:
My company sells smoke tubes that are used to track air currents in ventilation studies
and also to test respirators for proper fit per the OSHA irritant fume respirator fit test
protocol. Each smoke tube consists of a pencil-sized sealed glass tube filled with pumice
of ten tubes, so ten tubes are the minimum number we would ship at one time. To use the
granules coated with about one gram per tube of stannic chloride. They are sold in a box
rubes, they are activated by breaking off the ends and pushing ambient air through with a
small rubber bulb or motorized pump. Moisture in the air reacts with the stannic chloride
We began shipping these tubes in the fall of 1983 believing that they met a small
tubes was broken in transport. The broken tubes were activated by the sirrounding air
quantity labeling exemption for stannic chloride. Within the first year or two a package of
which caused them to produce smoke. The smoking package prompted a DOT official to
instruct us to label the packages as hazardous material. We were told that because the
Sine ta time (o, mid 15803) at be lin te smoke de in as it.:.
1827 and corrosive, and we have been paying the hazardous shipment fees on every
shipment.
azardous labeling. We share a common distributor who is questioning why our freigh
A competitor of ours ships a similar stannic chloride smoke tube product without the
harges include the hazardous fee and the competitor's do not. The competitor claims in
form letter to customers that the tubes meet a small quantity labeling exemption under 49
CFR Part 173.4.
100 D

<<<PAGE 3>>>

Is the competitor's claim valid? Do the small. quantity descriptions in 173.4 apply to
Sor abeing that does appry Can you est us if ten is thous another sin a uly try break.
for our smoke tube packages? Your consideration of this matter is much appreciated, and
we would like to receive a letter of interpretation for our files. Thank you for your kind
cooperation.
Sincerely,
Ron Roberan
Ron Roberson
Corporate Industrial Hygienist
& Technical Manager
200 7
ONE ENDORSNES
09906894LXE
- **truncated:** false