# Binex, Inc — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 02-0300
- **title:** Binex, Inc — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2003-04-08
- **effective on:** Not available
- **summary:** 02-0300 response to Binex, Inc concerning 172.101.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0300.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0300.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-02-0300
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2002/020300.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh St., S.W.
Special Programs
Research and
APR - 8 2003
Washington, D.C. 20590
Administration
Binex, Inc.
Mr. Gary I. Hansen
Ref. No. 02-0300
4410 South
Century Drive
Murray, UT
84123
Dear Mr. Hansen:
This is in response to your letter and subsequent telephone
applicability of the Hazardous Materials Regulations (49 CFR
conversation with a member of my staff concerning the
Parts 171-180 to a solution of sodium perchlorate.
you ask that the material be "correctly reclassified" as non-
Specifically,
regulated under the HMR because it does not meet the definition
for Class 5.1 (oxidizer) in S 173.127. You state your solution
contains 51% sodium perchlorate, 39% water, and 10% ethylene
form during transportation.
glycol, and that the ethylene glycol keeps
Under the HMR, unless an entry is preceded by a plus (t) sign in
Column (1) of the S 172.101 Table, a material listed by name that
using that description (see $ 172.101 (c) (12)).
does not meet the corresponding hazard class may not be described
containing 51% sodium perchlorate, as described in your letter,
If the solution
criteria for a Class 5.1 hazardous material. Provided the
does not crystalize during transportation, it does not meet the
solution does not meet
and is not a hazardous substance, hazardous waste, or a marine
the definition of any other hazard class,
pollutant, it is not regulated under the HMR.
I hope this information is helpful. If you have additional
questions, please do not hesitate
to contact this office.
Sincerely,
Regulatory Review and Reinvention
Hattie I. Mitchell, Chief
Office of Hazardous Materials Standards
172.101
020300

<<<PAGE 2>>>

•BINEX INC.
McIntyre
4410 South Century Drive • Murray, Utah 84123 • |(801) 268-2043 - FAX (801) 268-20473/12 r10(
Classification
02-0300
13 November 2002
Mr. Edward T. Mazzullo
Director, Office of Hazardous Materials Standards - DHM-10
Desearch and Special Fragrams Administration
400 7t St. S.W.
Washington, DC 20590
Dear Sir,
Binex has been working with an aqueous sodium perchlorate solution as an oxidizer in
binary explosives for many years.. We purchase the solution from Western Electro-
Chemical (WEECO) in Cedar City, Utah where it is labeled "oxidizer" and shipped in
concentrations of over 60% should be labeled "oxidizer." It is shipped to us as UN #
55-gallon drums at about 64% concentration. They indicate in their literature that
PREVENTINg
1502, hazard classification 5.2.
glycol (EG). This provides a very low freezing point of -40 degrees for meeting military
Binex blends the solution down to a concentration of 51% by adding water and ethylene
fioN.
applications. The final formulation is:
%
Sodium Perchlorate
51
Water
39
EG
10
Binex and the U.S. Army at Picatinny Arsenal (ARDEC) have cooperatively participated
in the development of this safe and effective solution. It is safe to manufacture, store and
ship. It is not flammable; has very low vapor pressure; no smell; no volatility; and can
be stored indefinitely in plastic containers.
The current use of this solution is in a binary explosive to aid the soldier in digging
quantity we can foresee shipping is about 60 Ibs packaged in a 5-gallon carboy.

<<<PAGE 3>>>

Page 2
Based upon the available commercial literature, and testing by the U.S. Army, Binex
the Oxidizer classification. Therefore, Binex recommends that this material be correctly
believes that this 51% Sodium Perchlorate Solution does not pose the hazard indicated by
reclassified to allow shipment as "Freight of All Kinds". Binex respectfully requests the
Office of Hazardous Materials Standards review the proposed hazard reclassification, and
provide any recommendations or comments.