# Arbonite — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 04-0005
- **title:** Arbonite — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2004-05-11
- **effective on:** Not available
- **summary:** 04-0005 response to Arbonite concerning 180.407.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0005.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0005.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0005
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040005.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh St., S.W.
Research and
Washington, D.C. 20590
Special Programs
Administration
MAY 11 2004
Mr. Lee K. Robinson
3826 Old Easton Road
Arbonite
Ref. No. 04-0005
Doylestown, PA 18901
Dear Mr. Robinson:
This responds to your December 22, 2003, letter requesting clarification on inspection of non-
DOT specification 407 and 412 cargo tanks constructed from glass fiber reinforced plastics
(GFRP) under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
Specifically, you ask whether these cargo tanks are subject to the "L" lining inspection under
§ 180.407(f) and the internal visual inspection "P" under § 180.407(e).
Cargo tanks constructed from GFRP are authorized only by DOT exemption. These DOT
exemptions, e.g., DOT E-11903 and DOT E-12516 enclosed, specifically waive Special
Provisions B15 and B23 in the HMR. These cargo tanks do not have a lining and, therefore, are
subject to the internal visual inspection requirements of § 180.407(e).
not subject to the lining inspection requirements of § 180.407(f). However, these cargo tanks are
I hope this answers your inquiry.
John A.
Chief, Standards Development
Gale
Office of Hazardous Materials Standards
Enclosures
180.409
040005

<<<PAGE 2>>>

Boothe
arbonite
§180.407
A DIVISION OF P & R INDUSTRIES, INC.
3826 OLD EASTON ROAD
Testing
DOYLESTOWN, PA 18901
P.O. BOX 888
215-345-1251 (FAX)
215-348-2950
04-0005
December 22, 2003
Research and Special Programs Administration
U.S. Department of Transportation
400 Seventh St. S. W.
Washington, D.C. 20590
Attention: Ms. Susan Gorsky
Senior Transportation Regulations Specialist
Office of Hazardous Materials
Dear Ms. Gorsky,
vehicles DOT 407 and DOT 412 that are constructed from glass fiber reinforced
I am writing with reference to (GFRG) non-DOT specification cargo tank motor
plastics. Do these tanks need the "L" lining inspection? If the answer is yes where
performed per regulation 180.407(e)?
Also, on the same tanks as listed above, is the internal visual inspection "p"
Thanks very much for your assistance. I will look forward to hearing from you as
quickly as possible.
Sincerely,
dek Fabum
Lee K. Robinson
Sales Manager
APPLICATORS OF PROTECTIVE COATINGS AND LININGS
- **truncated:** false