# Commonwealth of Virginia Department of State Police — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 04-0055
- **title:** Commonwealth of Virginia Department of State Police — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2004-04-07
- **effective on:** Not available
- **summary:** 04-0055 response to Commonwealth of Virginia Department of State Police concerning 178.345.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0055.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0055.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0055
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040055.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh St., S.W.
Special Programs
Research and
APR
7 2004
Washington, D.C. 2059(
Administration
Sergeant David P. Feather
Ref. No. 04-0055
Safety Division, Motor Carrier Safety
Commonwealth of Virginia
Department of State Police
P.O. Box 10900
Fairfax Station, Virginia 22039-0900
Dear Sergeant Feather:
This serves as a retraction of our September 25, 2003, response to your October 24, 2002 (Ref. No.
02-0287) letter requesting clarification on venting for double bulkheads or void spaces for MC 300
and DOT 400 series cargo tanks under the Hazardous Materials Regulations (HMR; 49 CFR Parts
171-180). Specifically, you asked whether it was permissible to plug the vent on top of the cargo tank
at the double bulkhead, provided that the bottom drain opening was left open. This follow-up letter is to
inform you that our previous response was incorrect.
Sections 178.340-7(c), 178.345-1(i)(2) and 178.345-3 require any MC 300 and MC 400 cargo tank
void or airspace to be vented and equipped with a drain, located on the bottom centerline, that is
accessible and open at all times. In our previous response, we indicated that it was permissible to plug
the vent on top of the cargo tank, provided the bottom opening or drain is open and operational at all
times. This is not correct.
The correct response to your question is that both the top vent and bottom drain must be kept open.
Vents are normally located in the top centerline of the tank and are required to communicate with the
vapor space in order to allow any gases that have accumulated in the void area to escape through the
vent located at the top of the tank. In the case of the void area, if the vent is plugged and there is a leak
in the bulkhead, the gas will drain out of the drain located at the bottom centerline of the tank, but the
vapors will have no means of escape if the vent is plugged. Further, if the bottom drain is closed or
plugged vi sid or dorio any no euranterise fom the top ent kill be abrid and beating.
an open vent and drain, thus allowing for vapors to escape, would be permissible.
We apologize for any inconvenience and hope this answers your inquiry.
Sincerely
C
/John A. Gate
Chief, Standards Development
-
Office of Hazardous Materials Standards
5178.345-1