# Compressed Gas Association, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 04-0221
- **title:** Compressed Gas Association, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2004-10-01
- **effective on:** Not available
- **summary:** 04-0221 response to Compressed Gas Association, Inc. concerning 180.407.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0221.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0221.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-04-0221
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040221.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh St., S.W.
Special Programs
Research and
Washington, D.C. 20590
OCT 1
Administration
2004
Mr. R. J. McGrath
Technical Manager
Compressed Gas Association, Inc.
Reference No. 04-0221
4221 Walney Road, 5"h Floor
Chantilly, VA 20151-2923
Dear Mr. McGrath:
This responds to your August 23, 2004 letter regarding the requirements for inspection and
testing of insulated MC-331 cargo tank motor vehicles (CTMVs) containing carbon dioxide,
refrigerated liquid under § 180.407 of the Hazardous Materials Regulations (HMR; 49 CFR Parts
171-180). You expressed concern about your members having to perform annual internal visual
inspections on their MC 331 CTMVs based on amendments to the HMR adopted in final rules
published under Docket No. RSPA 98-3554 (HM-213) on April 18 and September 3, 2003.
As shown in the table in § 180.407(c) of the HMR, insulated MC 331 CTMVs are excepted from
the requirement to have an annual internal visual inspection. This exception granted for MC 330,
MC 331, and MC 338 cargo tanks was not removed under the HM-213 final rule. Insulated MC
331 CTMVs are required to have an internal visual inspection at least once every five years.
Because the insulation prevents a complete external visual inspection, those items able to be
externally inspected must be inspected annually in accordance with 180.407(d) and noted in the
inspection report. The annual, partial external visual inspection and a leakage test performed in
accordance with § 180.407 (h) fulfill the annual inspection and test requirements applicable to
MC 331 CTMVs in carbon dioxide, refrigerated liquid service.
The HM-213 final rule amended the HMR to clarify the external visual inspection requirements
for insulated cargo tanks other than the insulated MC 330, MC 331, and MC 338s. As amended,
the HMR allows insulated cargo tanks equipped with manholes or inspection openings to have
either an internal visual inspection in conjunction with a partial external visual inspection or a
hydrostatic or pneumatic pressure test. See note 4 following the table in § 180.407(c) and
paragraph (d)(1).
I hope this information is helpful. If we can be of further assistance, please contact us.
Sincerely,
Hotte 2. Michel
for
Edward T. Mazzullo
Director, Office of Hazardous
Materials Standards
180,4076)
040221

<<<PAGE 2>>>

COMPRESSED GAS ASSOCIATION, INC.
4221 Walney Road, 5" Floor, Chantilly, VA 20151-2923
(703) 788-2700 • Fax: (703) 961-1831 • E-mail: cga@cganet.com • Web Site: www.cganet.com
Mitchell
August 23, 2004
$180.407 (0)
Mr. Frits Wybenga
Cargo Tanks
Research and Special Programs Administration
U.S. Department of Transportation
04-0221
400 Seventh Street SW
Washington, DC 20590-0001
Subject: 49 CFR 180.407
Gentlemen:
The Compressed Gas Association (CGA) seeks an opportunity to discuss with the DOT an
alternative to the requirements for internal and external visual inspections of MC 331 trailers
which deliver carbon dioxide refrigerated liquid (CO2) found at 180.407 (C) of 49 CFR
specifically with regard to subsection (d) as revised by HM213. CGA believes regulatory changes
to visual internal requirements promulgated in DOT Docket HM-213, which includes CO2
trailers with all other MC331 trailers, places an undue burden on the industry and is unnecessary
that due to the unique physical characteristics of CO2.
MC-331 cargo tanks are required to undergo periodic testing and requalification in accordance
with 180.407 (C). Pressure testing is required every 5 years and may be done either
pneumatically or hydrostatically at 1.5 times the design pressure of the vessel. Prior to any
pressure testing the inner vessel is required to undergo a visual inspection. Annual visual internal
inspections are required for "All insulated cargo tanks except MC331". CO2 trailers are MC331
and, thus, a yearly internal inspection is required. Docket HM-213 inserted the words "see note
4" to the table. Regrettably, the CGA did not have the opportunity to comment on the wording
inserting note 4 into the table, as this was not in the notice of proposed rule making.
The CGA is concerned that the additional inspections required by having a yearly internal
inspection causes risk to personnel without an additional level of safety. Additionally, internal
inspections on a yearly basis do not provide any higher level of safety as the product is non-
corrosive and the tank is outwardly protected by insulation. Personnel exposure to risk will
increase by a factor of five throughout the industry with the number of entries into a confined
space. Also, trailer purity and cleanliness is lost as opening the unit exposes the internal surfaces
to moisture, which adversely affects the food grade quality of the product. Trailers returning to

<<<PAGE 3>>>

service must be certified pure before filling. Internal inspections breed impurities into a sealed
system subjecting the carrier and customer to expensive gas chromatograph testing. In lieu of
performing this visual internal inspection, a shipper may choose to conduct pneumatic or
hydraulic pressure testing on a yearly basis. Yearly exposure of testing personnel to extremely
high energy levels created during pneumatic pressurization (necessary to protect product purity)
is dangerous. A typical CO2 vessel pressurized to 1.5 the MAWP has approximately 170 million
ft-lbs of potential energy.
The CGA operates a fleet of 3500 trailers within the CO2 industry. Through the years the
industry has taken hundreds of trailers apart restoring the foam insulation and replacing the outer
skin. We have examined bare vessels both inside and outside and have seen little or no
appreciable deterioration. By imposing yearly testing a cost of $2000 per trailer per year will be
seen by all carriers. Lost product and purging cost will be $1000 per trailer. In addition a trailer
must be taken out of service for a minimum of three days during the year. For an average fleet of
400 trailers, an additional $1,200,000 of maintenance would be required along with $240,000 for
rental to make up lost equipment.
In conclusion, the CGA wishes to discuss with DOT personnel an exclusion from the annual
visual internal inspection requirements. We feel reviewing the product properties with industry
experts and construction details with engineering and repair specialists would provide a better
understanding of the CO2 industry in general. This we hope will lead to an informed decision
about an alternative to annual internal visual inspection that provides an equivalent level of
safety for the CO2 industry.
Very Truly Yours,
COMPRESSED GAS ASSOCIATION
Technical Manager