# Girard Equipment, Inc — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 05-0243
- **title:** Girard Equipment, Inc — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2005-11-18
- **effective on:** Not available
- **summary:** 05-0243 response to Girard Equipment, Inc concerning 178.345, 180.407.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-05-0243.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-05-0243.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-05-0243
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2005/050243.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
Washington, D.C. 20590
400 Seventh Street, S.W.
ipeline anc
Administration
lazardous Materials Safet
NOV 1 8 2005
Mr. John L. Freiler
Ref. No. 05-0243
Girard Equipment, Inc
Linden, NJ 07036
3301-A Tremley Point Rd, Suite 7
Dear Mr. Freiler:
This is in response to your request to Mr. Danny Shelton, Federal Motor Carrier Safety
Administration, U.S. Department of Transportation, for a written clarification of certain
venting requirements for cargo tanks under the Hazardous Materials Regulations (HMR;
49 CFR Parts 171-180), as discussed at a recent Truck Trailer Manufacturers
Association/National Tank Truck Carriers Conference in Louisville, Kentucky. We have
framed our response in the enclosed series of questions and answers.
I hope this information is helpful. Please contact this office should you have additional
questions.
Sincerely,
•Susan Gorsky
Acting Director
Office of Hazardous Materials Standards
Enclosure
cc: Mr. Danny Shelton, FMCSA
178.345-10
(78.342-26)
180.407
050243

<<<PAGE 2>>>

of Transportation
U.S. Department
Washington, D.C. 20590
400 Seventh Street, S.W.
Pipeline and
Administration
Hazardous Materials Safety
NOV 18 2005
Ms. Rosemary Muellner
Fort Vale
Ref. No. 05-0243
126 North Virginia
La Porte, Texas 77571
Dear Ms. Muellner:
This is in response to your request to Mr. Danny Shelton, Federal Motor Carrier Safety
venting requirements for cargo tanks under the Hazardous Materials Regulations (HMR;
Administration, U.S. Department of Transportation, for a written clarification of certain
49 CFR Parts 171-180), as discussed at a recent Truck Trailer Manufacturers
Association/National Tank Truck Carriers Conference in Louisville, Kentucky. We have
framed our response in the enclosed series of questions and answers.
I hope this information is helpful. Please contact this office should you have additional
questions.
Sincerely,
Xin My
Susan Gorsky
Acting Director
Office of Hazardous Materials Standards
Enclosure
cc: Mr. Danny Shelton, FMCSA
178.345-10
178.342-2 6)
180,407
050243

<<<PAGE 3>>>

Transportatio
S. Departme
400 Seventh Street, S.W.
Washington, D.C. 20590
ipeline anc
Administration
lazardous Materials Safet
NOV 18 2005
Mr. Chad Betts
Ref. No. 05-0243
Betts Industries
1800 Pennsylvania Avenue West
Warren, Pennsylvania 16365-0888
Dear Mr. Betts:
This is in response to your request to Mr. Danny Shelton, Federal Motor Carrier Safety
dministration, U.S. Department of Transportation, for a written clarification of certai
enting requirements for cargo tanks under the Hazardous Materials Regulations (HMR
49 CFR Parts 171-180), as discussed at a recent Truck Trailer Manufacturers
Association/National Tank Truck Carriers Conference in Louisville, Kentucky. We have
framed our response in the enclosed series of questions and answers
I hope this information is helpful. Please contact this office should you have additional
questions.
Sincerely,
Susan Gorsky
Acting Director
Office of Hazardous Materials Standards
Enclosure
cc: Mr. Danny Shelton, FMCSA
178.345-10
178.342-2(b)
180.407
050243