# Supervac 2000 — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 06-0160
- **title:** Supervac 2000 — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2006-10-05
- **effective on:** Not available
- **summary:** 06-0160 response to Supervac 2000 concerning 178.345.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0160.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0160.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0160
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2006/060160.pdf
**body:**

<<<PAGE 1>>>

f Transportatic
.S. Departme
400 Seventh Street, S.W
Washington, D.C. 20590
peline and Hazardol
aterials Safety Administratic
OCT
5 2006
Ms. Nathalie Doyon
1043 Rue Renault
Supervac 2000
Ref. No. 06-0160
St-Jean-Chrysostome, Qc G6Z1B6
Dear Ms. Doyon:
This responds to your fax dated July 14, 2006 requesting clarification on tank outlets for
(HMR; 49 CFR Parts 171-180). Specifically, you ask if a double acting valve driven by a
cargo tank motor vehicles in $178.345-11(b)(2) of the Hazardous Materials Regulations
self-closing air valve at the top of the tank meets the provisions of §178.345-11(b)(2).
According to your fax, and as a follow up question to your first response from us on this
subject dated July 11, 2006 under Ref. No. 06-0035, your modified diagram shows a valve
that is not self-closing, but utilizes a double acting valve driven by a self-closing air valve.
You ask for review of your modified diagram regarding compliance with provisions in
§178.345-11(b)(2).
Section 178.345-11(a) requires cargo tank outlets, closures, and associated piping to be
protected in accordance with $178.345-8. In addition, §178-345-11(b)(1) requires each
cargo tank loading/unloading outlet be equipped with an internal self-closing stop-valve, or
wall. Each loading/unloading outlet must be fitted with a self-closing system capable of
alternatively, with an external stop-valve located as close as practicable to the cargo tank
closing all such outlets in an emergency within 30 seconds of actuation. During normal
operations the outlets may be closed manually. Under $178.345-11(c)(2), bottom loading
outlets that discharge lading into the cargo tank through fixed internal piping above the
maximum liquid level of the cargo tank need not be equipped with a self-closing system.
it is the opinion of this Office that the valve depicted in the diagram accompanying your
letter does conform to $178.345-11(b)(2) provided it is connected to the emergency valve
and closes the top of the tank.
I hope this answers your inquiry.
Sincerely,
John A. Gale
Office of Hazardous Materials Standards
Chief, Standards Development
178.345-11(b)(2)
060160

<<<PAGE 2>>>

:...
Boothe
SUPERVAC
§ 178.345-11(6) 2)
2000inc.
arao
Tarks
06-0/66
FAX TRANSMISSION
To:
Mrs. Deborah Boothe and/or
Mr. John A. Gale
Phone:
Hazardous Materials
Fax:
(202) 366-3012
(202) 366-4545
From:
Nathalie Doyon
Supervac 2000
Phone:
1043, rue Renault, St-Jean-Chrysostome, Qc G6Z 1B6
Fax:
(418) 839-5702
(418) 839-1816
Object: Following your letter
Date: July 14, 2006
If you did not receive that number of pages, please contact us at the following telephone no (418) 839-5702
We are sending you 2 pages including this covering page.
MESSAGE
Good day:
Ve received your letter dated July 11' 2006, whore you were mentioning that the manual double action valv
you another way that we could do things in order to be conform.
epicted in the diagram we provided does not conform to 178.345-/1. Following that, we would like to present t
As you will notice on the attached modified sketch, the valve still won't be a self closing valve but we will use a
double acting valve driven by a self closing air valvc (see drawing).
We would appreciate to have an answer froin you as soon as possible. If you need more details concerning the
sketch or any other information, plcase don't hesitate to contact us.
Once again, thank you for your collaboratior
Regards
Nathalie
Supervac 2000
ndoyon@supervac2000.com
Have a nice day O
200/1000