# ExxonMobil Chemical Company — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 06-0280
- **title:** ExxonMobil Chemical Company — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2007-09-20
- **effective on:** Not available
- **summary:** 06-0280 response to ExxonMobil Chemical Company concerning 180.605.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0280.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0280.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-06-0280
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2006/060280.pdf
**body:**

<<<PAGE 1>>>

1200 New Jersey Avenue, SE
Washington, D.C. 20590
pateiats nd Hazardous
Administration
SEP 20 2007
ExxonMobil Chemical Company
Mr. Ronald J. Stokes
Ref. No. 06-0280
Intermediates, Synthetics Product Stewardship
P.O. Box 3140
Edison, New Jersey 08818
Dear Mr. Stokes:
This responds to your December 20, 2006 letter requesting clarification on the retesting and
recertification requirements for portable tanks under §180.605 of the Hazardous Materials
Regulations (HMR; 49 CFR Parts 171-180) and Special Permit DOT-SP-11167.
According to your letter, you use portable tanks exclusively for the transport of a Pyrophoric
solid, inorganic, n.o.s., UN 3200, PGI catalyst. Specifically, you ask: 1) what qualifications
a testing facility and/or tester must have; 2) if there is an option between air and hydrostatic
testing under §180.605(h); and, 3) whether PHMSA has a list of qualified testing facilities.
Section 180.605 authorizes the use of either air or hydrostatic testing for recertification of
DOT specification portable tanks. Special Permit DOT- SP-11167 authorizes the use of non-
DOT specification portable tanks under certain conditions. In accordance with the terms of
the special permit, a new tank must be hydrostatically pressure tested for one hour and
hydrostatically retested and reinspected at least once every five years thereafter, as specified
in §180.605 for DOT Specification 51 portable tanks at the original qualification test gauge
pressure specified in Special Permit DOT-SP-11167, for a period of 15 minutes. There is no
requirement in $180.605 for tests to be performed by an approved third party testing agency.
Qualified testers are required to be trained in accordance with the HMR. If the tank is an
The tank owner or user may have the tank inspected and tested by any qualified tester.
ASME tank, the inspection and testing must be performed by a qualified ASME tester.
I hope this answers your inquiry.
Sincerely.
Chief, Standards Development
Office of Hazardous Materials Standards
180.605
060280

<<<PAGE 2>>>

12/20/2006 08:01
7323216057
PRODUCT STEWARDSHIF
01/01
Boothe
Intermediates, Synthetics Product Stewardship
ExxonMobll Chemical Company
Edison, New Jersey 08818
P.O. Box 3140
$180.605
732 321 6033 Telephone
732 321 6057 Facsimlle
Testing of Portable Tanks
06-0280
ExonMobil
December 20, 2006
Chemical
Pipeline and Hazardous Matcrials Safety
U.S. Department of Transportation
400 7th Street, S.W.
Administration (PHH-10)
Washington, DC 20590-0001
Attn: Mr. Edward T. Mazzullo, Director
Office of Hazardous Materials Standards
Ref: DOT SP-1) 167
49 CFR $180.60S
Dear Mr. Mazzullo:
several portablc tanks constructed and tested by Eco-Pak (now Columbiana Boiler Company. LLC) and allowed
Pursuant to the stated references I submit the following for your consideration and response. We currently have
for hazmat transport under a special permit. We use these tanks exclusively for the transport of a Pyrophoric
solid, inorganic, n.o.s. UN3200 PGI catalyst. Pursuant to DOT SP-11167 paragraph 7b and the requirements a
}180.605 five year testing and recertification must be completed for each tank which gives rise to the following
1. Pursuant to the examination & test requirements in paragraphs (g) and (h) of $180.605; what qualifications.
2. Pursuant to paragraph (h) of $180.605 is there an option between air and hydrostatic testing? If not, which
if any, must a testing facility and/or tester have?
3. If the tanks must be hydrostatically tested, does PHMSA have a list of qualified testing facilities?
one must be performed?
Since the retest due date is close, a prompt response would be apprecated.
Should there be any questions concerning this request, I may be contacted at the above address or contact
numbers shown below.
Thanks for your help in this matter.
Sincerely,
Paani State
Ronald J. Stokes
Tcl (732) 321-6046
Fax (732) 321-6057
Email: ron.j.stokes@exxonmobil.com